The  internal  short  circuiting  of  the  UPS  will  lead  to  dangers  such  as 

electric shock or fire; therefore do not allow liquids or any foreign object to 

enter the UPS. No water containers (such as a water glass) or any other 

liquid-containing vessels shall be placed on the top of the UPS so as to 

avoid such dangers as electric shock. 

 

Please do not use the UPS in excess of the rated load capacity. 

 

Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 

 

Risk  of  electric  shock,  do  not  attempt  to  disassemble  the  unit.  No  user 

serviceable parts inside. Refer servicing to qualified service personnel. 

 

If UPS is to be stored for a long time, it is recommended to recharge the 
batteries  (by  connecting  the  utility  power  to  UPS,  switch  “ON”),  once  a 
month for 24 hours to avoid a full battery discharge. 

 

In  case  smoke  is  found  coming  out  from  the  device,  please  cut  off  the 

power supply quickly and contact the distributor. 

 

The UPS contains one/two large-capacity batteries. So the shell shall not 

be  opened,  otherwise  such  dangers  as  electric  shock  will  be  caused.  If 

any  internal  overhaul  or  replacement  of  the  battery  is  required,  please 

contact the distributor. 

 

Servicing  of  batteries  should  be  performed  or  supervised  by  personnel 

knowledgeable  of  batteries  and  the  required  precautions.    Keep 

unauthorized personnel away from batteries. 

 

A  battery  can  present  a  risk  of  electrical  shock  and  high  short  circuit 

current. The following precautions should be observed when working on 

batteries: 

o

  Remove watches, rings, or other metal objects from the hand. 

o

  Use tools with insulated handles and wear rubber gloves and boots. 

o

  Do not lay tools or metal parts on top of batteries. 

o

  Disconnect  charging  source  prior  connecting  or  disconnecting 

batteries terminals. 

 

When replacing batteries, replace with the same type and number of the 

sealed lead-acid batteries. 

 

The maximum ambient temperature rating is 40°C. 

Summary of Contents for VI 1000T/HID

Page 1: ...Line Interactive UPS PowerWalker VI 500T HID PowerWalker VI 750T HID PowerWalker VI 1000T HID PowerWalker VI 1500T HID Quick Start Guide EN...

Page 2: ...EN...

Page 3: ...Introduction 4 2 Description of Features 4 3 Package Contents 4 4 Product Overview 5 5 Installation and Initial Startup 7 6 Functions Operation 10 7 Software Installation on your PC 11 8 Maintenance 1...

Page 4: ......

Page 5: ...lt in shock hazard as well as violate local electrical codes To reduce risk of overheating the UPS do not cover the UPS cooling vents This unit intended for installation in a controlled environment te...

Page 6: ...device please cut off the power supply quickly and contact the distributor The UPS contains one two large capacity batteries So the shell shall not be opened otherwise such dangers as electric shock...

Page 7: ...th disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the...

Page 8: ...longer and more reliability 2 Description of Features Easy to use and install utilized microprocessor control to maximize the reliability and efficiency Equipped with built in boost and buck AVR func...

Page 9: ...Rear Panel VI 500T 750T VI 1000T 1500T AC input RJ11 RJ45 LAN Modem phone line protection USB port IEC outlet AC input RJ11 RJ45 LAN Modem phone line protection USB port IEC outlet Fan ON OFF button S...

Page 10: ...no activity for 3 minutes 1 In low sensitivity mode Lo UPS will tolerate more fluctuations in power and will go on battery power less often If the connected load is sensitive to power disturbances ke...

Page 11: ...ve contaminants Please place the UPS away from other units at least 20 cm to avoid interference Do NOT operate the UPS where the temperature exceeds 0 40 C and the humidity is over 0 90 RH II Connect...

Page 12: ...line for Surge Protection Connect for example a single modem or phone line into surge protected IN outlet on the back panel of the UPS unit Connect from OUT outlet to the computer with another phone l...

Page 13: ...PS unit by pressing the On Off button Turn off the UPS unit by pressing again the On Off button NEVER connect a laser printer or scanner to the UPS unit because in rush current generated by motor s de...

Page 14: ...it will automatically shut down after 5 minutes for energy saving while running on battery mode Disable by default The UPS will restart while AC recovery The green power function can be enable only b...

Page 15: ...saving and system shut down functions it can also send warning messages via SMS e mail etc Use the bundled CD and follow the on screen instructions to install the software Enter the following serial...

Page 16: ...ype Never short circuit batteries When working with batteries remove watches rings and other metal objects and only use insulated tools III Battery module replacement Battery tray removal on tower mod...

Page 17: ...ure safety and high performance use only batteries supplied by BLUEWALKER Take care to firmly press together the two parts of the connector during remounting C Remove the metal protection cover in fro...

Page 18: ...he UPS Verify that the load matches the UPS capability specified in the specs 2 Power cord is loose Reconnect the power cord properly When power failure back up time is shorten 1 Overload of the UPS 1...

Page 19: ...to 40 C non condensing Noise Level Less than 40dB Less than 40dB Line mode Less than 45dB Battery mode Software Monitoring Software WinPower included CAPACITY 500VA 350W 750VA 500W 1000VA 700W 1500VA...

Page 20: ...16 EN 614 01858 00...

Reviews: