Required Operating Conditions and Extended Five-Year Pro-Rated Warranty Exclusions
1. If you plan to store the UPS or battery cabinets prior to use, store them in a cool, dry environment.
Storage temperature should not exceed 95°F (35°C) in order to preserve battery life. For longer term
storage, energize the UPS and battery cabinet for approximately 8 hours every 90 days in order to
maintain battery charge. Whenever the units are not energized, verify that the circuit breaker on all
battery cabinets is returned to the OFF (O) position.
2. Average annual temperature at equipment site shall not exceed 77°F (25°C).
3. The above warranty does not apply to units with broken or damaged enclosures, input cables or out
put receptacles, or to units that have been frozen or damaged due to neglect, accident, or abuse such
as fire, flooding, explosives, or exposure to weather conditions.
4. The above warranty also does not apply to units that have been improperly installed, altered, or
tampered with in any way, or if the equipment was not used under normal operating conditions and in
accordance with labels and instructions.
Extended Five-Year Pro-Rated Warranty Claims Procedure
Powerware will not accept any product for return, credit, or exchange unless expressly authorized by
Powerware in writing and delivered to F.O.B. Powerware's factory. Nor will Powerware be responsible
for any charges for testing, checking, removal, or installation of a warranted UPS or component part of a
UPS.
All defective UPS units and parts, when returned and replaced, become the property of Powerware.
This warranty applies only to the original end user of the equipment and is nontransferable.
$50,000 Computer/Load Protection Guarantee
For the lifetime of the original purchaser who has filed the Warranty Registration, Powerware promises to
repair or replace (at Powerware's option) equipment (valued up to $50,000) that is damaged by an AC
power line surge, spike, or other transient when properly connected to Powerware's UPS (reimbursement
for or restoration of data loss excluded). This guarantee applies only in all of the following circum-
stances:
1. The UPS is plugged in to properly grounded and wired outlets using no extension cords, adapters,
other ground wires, or other electrical connections.
2. The installation of the UPS complies with all applicable electrical and safety codes described by the
AS/NZ Standards.
3. The UPS was used under normal operating conditions and in accordance with all labels and
instructions.
4. The UPS was not damaged by accident (other than AC power line transient), misuse, or abuse.