ITS-12 User Manual

Operation 

 

 

 

 

The  voltage  sensing  ITS-12  is  an  automatic  switch 

designed  for  12  volt  vehicle  electrical  systems  with 

negative ground. The model ITS-12 is rated at 35 amps 

continuous  duty.    Using  the  10  position  rotary  switch, 

you  can  select  one  of  the  following  timer  settings  of: 

2, 15 or 30 minutes and 1, 2, 3, 4, 5, 8 & 12 hours.  In 

addition, each setting also includes a LVD (Low Voltage 

Disconnect) threshold as well. See table on right.

Two built-in LED lights show the current status.  When 

the engine is running, a solid GREEN LED light means the 

timer  is  passing  power  through  the  unit  (13.0~14.5V).  

When the vehicles engine is shut off, a voltage drop will 

occur and a slow FLASHING GREEN LED light is displayed 

and  turns  ON  the  timer  (below  12.8V).  A  red  flashing 

LED  light  will  display  when  its  output  power  to  your 

electronics  reaches  the  users  preset  timer  setting  (2 

minutes to 12 hours).  No ignition connection is required.

ITS-12 includes an Over Voltage Protection System which 

will automatically shut off your electronics if the voltage 

reaches over 16 volts. A solid RED LED light will display 

until the over voltage condition is corrected.

Hook-up & Installation

The  ITS-12  should  be  installed  in  between  the  vehicle 

battery and the DC load. Typically, the load is a two-way 

mobile  radio,  mobile  computer  and  other  vehicle  DC 

electronics. Standard installation involves installing the 

ITS-12 in between the battery and the DC feed side of the 

radio using the supplied ring terminals. When installing 

the ITS-12, you need to connect (positive and negative 

DC  power IN & positive and  negative DC  power OUT). 

No  ignition  connection  is  required.  This  model  can  be 

installed inside of the vehicle or engine compartment as 

these units are waterproof.

CAUTION: Make sure you connect the + / – leads to the 

correct  polarity  on  both  input  and  output.  Make  sure 

you also use the supplied star washers and do not over 

tighten the ring terminal screws.

Rotary Switch Settings

Set the Rotary Selector to 

the desired setting.

Use 

small 

flat 

screwdriver to change the 

rotary switch position. 

Detailed  settings  are  also 

located on the side of your 

unit.

Emergency Override Switch

An extra ring terminal position (AUX) is located next to the 

LED lights.  By momentary applying 12V to this terminal 

(with a user supplied switch) it will automatically override 

and energize the timed out timer and/or LVD condition 

and give you 15 minutes of emergency operation time.

0:

2 m

11.4 LVD

1:

15 m 11.4 LVD

2:

30 m 11.0 LVD

3:

1 hr

11.4 LVD

4:

2 hr

11.4 LVD

5:

3 hr 11.0 LVD

6:

6 hr 11.4 LVD

7:

7 hr

11.4 LVD

8:

8 hr 11.0 LVD

9:

12 hr

11.0 LVD

ITS-12 ▪ Rev 4/2015

OUTPUT

+

-

INPUT

LED

AUX SWITCH

+

-

R

G

To Electronics

To Battery

ÑITS-12=Ó

DC Timer/LVD Battery Guard 