Specifications
•
Amperage Rating:
35 Amps max @ 12V continuous
duty
•
Low Standby Current Draw:
5mA in standby mode,
100 mA normal operation mode
•
Compact Size:
3½”L x 2”W x 1½”H
•
Weight:
0.5 lbs. (229 grams)
•
Construction:
Potted water proof design. Can be
mounted inside an engine compartment.
•
LED Status Indicators:
o
Solid Green LED light = Timer OFF power passing
through
o
Flashing Green LED light = Timer ON
o
Flashing Red LED light = Timer has expired, load
is OFF
o
Slow Flashing Red LED = LVD Condition
o
Solid Red LED light = Overvoltage Condition
•
Connections:
+/- Power IN from Battery. +Power
OUT to electronics, negative is optional on OUT (no
ignition wire required). Emergency Override Switch.
Troubleshooting
Unit will not turn ON:
•
Check for reverse polarity on Input and Output
connections
•
Check that Battery power is connected to the Input
connection
LED Lights Not Working:
•
Check (-) Negative input connection for good ground
to battery
•
Check Input (+) positive connection
Red LED Light Solid ON:
•
Alternator is defective putting out over 16V, reduce
output below 15V, unit will auto-reset
Warranty:
Powerwerx support policy is simple; we want you to be
happy! If you have a problem, please feel free to contact
us and we will do our best to get you up and running as
soon as possible.
The Powerwerx ITS-12 has a one-year limited warranty.
We will repair or replace your ITS-12 if you encounter any
problems within one year of purchase. We reserve the
right to charge a reasonable fee for repairing units with
user-inflicted damage. It is your responsibility to ship
the defective unit back to Powerwerx. We will pay for
shipping the replacement to you within the warrantee
period.
ITS-12 ▪ Rev 4/2015
Also Look at our Other Models:
LVD-35 – DC Low Voltage Disconnect
•
Heavy Duty design rated at 35A continuous
duty
•
LVD includes user selectable disconnect settings
of: 10.6, 10.8, 11.0, 11.2, 11.4, 11.6, 11.8, 12.0,
12.1, 12.2 VDC
•
Auto Reconnects when Voltage returns to safe
level
APS-12 – DC Automatic Power Switch/Timer
•
No ignition connection required: Automatic
On/Off Operation
•
Ideal for all 2-way radios, computers and DC
electronics – 25A current rating
•
User selectable timer positions (2, 15, 30
minutes, 1, 2, 3, 4, 5, 8, 12 hours)
More information at: www.powerwerx.com
ITS-12 User Manual
ÑITS-12=Ó
23695 Via Del Rio, Yorba Linda, CA 92887 ▪ 714-674-0073 Phone ▪ 714-674-4949 Fax