background image

Specifications

• 

Amperage Rating: 

35 Amps max @ 12V continuous 

duty

• 

Low Standby Current Draw: 

5mA in standby mode,  

100 mA normal operation mode

• 

Compact Size:  

3½”L x 2”W x 1½”H

• 

Weight:  

0.5 lbs. (229 grams)

• 

Construction: 

Potted  water  proof  design.  Can  be 

mounted inside an engine compartment.

• 

LED Status Indicators:

 

o

Solid Green LED light = Timer OFF power passing 

through

 

o

Flashing Green LED light = Timer ON 

 

o

Flashing Red LED light = Timer has expired, load 

is OFF

 

o

Slow Flashing Red LED = LVD Condition

 

o

Solid Red LED light = Overvoltage Condition

• 

Connections:

  +/-  Power  IN  from  Battery.    +Power 

OUT to electronics, negative is optional on OUT (no 

ignition wire required). Emergency Override Switch.

Troubleshooting

Unit will not turn ON: 

• 

Check  for  reverse  polarity  on  Input  and  Output 

connections

• 

Check that Battery power is connected to the Input 

connection

LED Lights Not Working:

• 

Check (-) Negative input connection for good ground 

to battery

• 

Check Input (+) positive connection

Red LED Light Solid ON:

• 

Alternator is defective putting out over 16V, reduce 

output below 15V, unit will auto-reset

Warranty:

Powerwerx support policy is simple; we want you to be 

happy! If you have a problem, please feel free to contact 

us and we will do our best to get you up and running as 

soon as possible.

The Powerwerx ITS-12 has a one-year limited warranty. 

We will repair or replace your ITS-12 if you encounter any 

problems within one year of purchase. We reserve the 

right to charge a reasonable fee for repairing units with 

user-inflicted  damage.  It  is  your  responsibility  to  ship 

the defective unit back to Powerwerx. We will pay for 

shipping the replacement to you within the warrantee 

period.

ITS-12 ▪ Rev 4/2015

Also Look at our Other Models:

LVD-35 – DC Low Voltage Disconnect

• 

Heavy  Duty  design  rated  at  35A  continuous 

duty

• 

LVD includes user selectable disconnect settings 

of: 10.6, 10.8, 11.0, 11.2, 11.4, 11.6, 11.8, 12.0, 

12.1, 12.2 VDC

• 

Auto Reconnects when Voltage returns to safe 

level

APS-12 – DC Automatic Power Switch/Timer

• 

No  ignition  connection  required:  Automatic 

On/Off Operation

• 

Ideal  for  all  2-way  radios,  computers  and  DC 

electronics – 25A current rating

• 

User  selectable  timer  positions  (2,  15,  30 

minutes, 1, 2, 3, 4, 5, 8, 12 hours)

More information at: www.powerwerx.com

ITS-12 User Manual

ÑITS-12=Ó

23695 Via Del Rio, Yorba Linda, CA 92887 ▪ 714-674-0073 Phone ▪ 714-674-4949 Fax

Reviews: