- 6 -
WARNING:
This machine is designed to work in closed industrial environments on
level floors or on inclines no steeper than 2%. Do not use inflammable
chemicals and/or explosives with this machine.
Floor wiper:
Inspect and clean the floor wiper weekly and make sure to
restore it to its working condition. If the drying action is not perfect after
cleaning the wiper assembly, remove and re-place any worn rubber blades.
Brush:
The brush must be kept in working order; to remove a worn brush
proceed as follows (follow the procedure in reverse to reassemble):
- Turn off the machine (key switch in OFF position) and lift the brush with
the pedal provided (
M9
);
- Release the catch
M15
and remove the rubber spray guard;
- Turn the brush to be re-moved by hand until the coils of spring M19
are accessible;
- By closing together the coils of spring
M19
with your fingers (as if you
where closing a pair of scissors) the brush will free itself;
- The machine is supplied with a Nylon brush; brushes made of Tynex,
broom corn or steel are also available, as well as disc fixtures to which
discs can be mounted: Black for thorough cleaning of particularly dirty
floors; Green for linoleum floors; Yellow for marble:
Waste Tank: clean the tank every week as follows: lift the cover; remove the
motor stop ring
M13
and remove the suction motor from its seat; carefully
clean the filter, net and sponge, and remove the dirt which has accumulat-
ed in the tank, by water jetting. To ease the operations detach the discharge
assembly
M2
by unscrewing its side knobs.
Batteries:
Check the electrolyte level and top up with distilled water if
drops below the level of the battery elements. Keep the batteries clean and
dry with anti-static cloths. Recharging must be carried out with the cell
plugs removed and the cover of the machine opened so as to allow the
gases generated to escape.
In confined spaces the-se gases can be explosive, so recharging should be
done in a well-ventilated area.
NORMS FOR BATTERIES SAFETY.
It is necessary to remember that the
batteries produce gas that can provoke explosions if they come in contact
with flames and sparks. Do not perform reparations on a battery while it’s
recharging. Don’t leave tools or metallic parts on the battery. Always clean
up and dry the batteries; the connections must be covered with anti-acid
grease or petroleum jelly. Take care that the battery tank is always cleaned.
IN CASE OF ACID LOSS FROM THE BATTERIES:
replace the battery
with the loss respecting the polarities and the connections shown above.
For this operation use rubber gloves, apron and glasses to protect the skin
and the eyes.
Summary of Contents for PAS28032DX
Page 15: ... 14 ...
Page 16: ...A Tacony Company 3101 Wichita Court Ft Worth TX 76140 1755 ...