Prior to using the Powr-Zone ozone generator, determine the
source of the odor and remove any odor causing substance that
can be found. If the odor is from a wet or flooded situation, dry
the entire area well before starting the ozonation procedure.

1. Make certain all people, pets and plants are out of the area. 

Close all windows and doors. Place a safety sign on the door 
to the location warning of Ozone use –

DO NOT ENTER.

2. Place the Powr-Zone unit on a shelf or tabletop as high in 

the area to be treated and if possible, near the AC return. 

NOTE:

Ozone is heavier than air and will fall to the bottom of

the room. For best results place an air mover at a 45 degree
angle, pointed towards the wall to create a circular air movement.

3. Set the air conditioning thermostat on constant fan and adjust 

the temperature control to a low (cold) setting. If AC is not 
available, use air movers for more effective treatment. 

NOTE:

Ozone generators work best in a cool, low humidity envi-

ronment. With the AC on, you also receive a secondary benefit of
purifying the inside of the ductwork. This is also true for ozoning
automobiles. Smoke and stale odors will stay in a car’s AC ducts
if you do not run the AC during ozoning. 

4. Plug the power cord into a grounded, 3-prong outlet. 
5. To set the timer, turn the dial to “12” and then back to 

desired length of time.

6. Leave the area immediately. Do not return until set time 

plus 20 minutes has expired.

7. After time has expired, open all windows or doors to air out 

for 20 minutes.

NOTE:

Ozone destroys odor-causing molecules. The length of

time this process takes will vary depending on variables such as
pollutant load, temperature, humidity, etc. and the amount of area
being treated. The ozone process can produce a haze in the air
within the area being treated.

CAUTION

DO NOT BREATHE HIGH LEVELS OF OZONE. OZONE IN
CONCENTRATIONS ABOVE 0.04 PPM IS CLASSIFIED AS AN
UPPER RESPIRATOR IRRITANT AND MAY BE CONSIDERED
UNHEALTHY IN OCCUPIED AREAS. THIS MODEL OZONE
GENERATOR IS INTENDED FOR USE IN UNOCCUPIED
AREAS ONLY. THIS OZONE GENERATOR SHOULD BE TIMED
TO TURN OFF AT LEAST 20 MINUTES PRIOR TO REENTRY
OF TREATED AREA. TREATED AREA SHOULD BE AIRED OUT
PRIOR TO REENTERING TO PREVENT EXPOSURE TO HIGH
LEVELS OF OZONE.

TROUBLESHOOTING

Problem

Possible Cause

Solution

Unit does not turn on

Power cord not plugged in.

Plug power cord into suitable outlet 
with correct voltage.

Circuit breaker is tripped.

Reset circuit breaker at panel box.

Faulty power outlet.

Try another outlet.

Fuse is blown on back of unit

Replace fuse.

Unit keeps blowing 

Too small amperage fuse is

Replace fuse with correct rated (1A) fuse. 

Fuses.

being used

Electrical short circuit.

Return unit to manufacturer for repair.

Unit does not

Damage to unit.

Return unit to manufacturer for repair.

produce ozone.

To calculate the time to remove the odor or to purify an area:

(x cubic feet ÷ 100 CFM) x 2 = time setting

example:

(1000 cubic foot room ÷ 100) x 2 = time setting
10 x 2 = time setting
20 minutes = time setting