background image

4

General instructions for PFX1380 series Extractors

Congratulations on your purchase of a Powr-Flite extractor. You are now equipped to handle any and al 
commercial carpet cleaning jobs.

Shipping and Damage

This equipment is thoroughly inspected, tested, and packaged to provide equipment in good operating 
condition. It is beyond our control after the equipment is turned over to a freight carrier. The freight 
carrier received and signed for the equipment in good condition. Consequently, it is most important to 
protect your interest by carefully complying with the following instructions:
Please inspect your cartons for any damage (including concealed damage) that might have occurred dur-
ing shipment. Any damage is the responsibility of the freight carrier and should be reported to the freight 
carrier immediately. It is your responsibility to issue a claim and to receive compensation from the freight 
carrier for any damage done in transit. Damage of this sort is not warranted.

Follow these easy step by step instructions to ensure proper operating performance.

1.  Fill up the fresh water solution tank with tap 

water that is 120-135 degrees and approved 
carpet cleaning chemical if you are not pre-
spraying your chemical on the carpet.

2.  Attach two 12 gauge extension cords (NOT 

INCLUDED) (one cord for non-heated mod-
els) to each of the pigtail cords located on the 
lower backside of the unit. The red pigtail pow-
ers the heater while the black pigtail powers 
the vacuum motors and pump.

3.  Plug each extension cord into a separate and 

grounded 20 amp wall socket circuits, when 
this is accomplished the green indicator light 
will be lit (on heated models).

4.  Attach the hose system to the unit and to your 

carpet wand.

5.  Turn on the heater and the pump to the “on” 

position, (only pump on non-heated models) 
when the heater is on the orange indicator light 
on the switch panel will be lit.

6.  With the solution line attached to the wand and 

the machine, prime the pump by squeezing the 
trigger on the wand releasing the water (hold 
wand tip over solution tank to put water back 
into solution tank).  This will pump water into 
the heater and get any air out of the solution 
line. Let the heater heat up this will take 3 to 5 
minutes. *Prime pump on 400 p.s.i. models with 
prime hose (included).

7.  Turn vacuum switches to the “on” position one 

at at time to begin cleaning. 

8.  Anyone designated to operate this equipment 

must, without fail, read and thoroughly under-
stand all instructions and precautions prior to 
use.

9.  Never use equipment out of doors or in the 

rain.

10.  Never use flammable or explosive materials in 

or around this equipment!!!

11.  When vacuum tank is full, empty by using 

drain hose at rear of machine. If a pail is used 
to empty the vacuum waste tank, do not use 
the same pail to fill the solution tank as this can 
result in putting dirt and grit into the solution 
line that can plug filters, orifices, and generally 
degrade the solution line system (do not reuse 
solution).

12.  To empty solution tank, detach the wand from 

the end of the vacuum hose and insert the 
vacuum hose into the solution tank.  Turn the 
vacuum switches to “on” position and transfer 
solution to vacuum tank and dispose of as out-
lined in #11. Clean vacuum stack filter at this 
time.

Summary of Contents for PFX1380 SERIES

Page 1: ...WARNING OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT Upright Extractor OPERATORS MANUAL AND PARTS LIST Model PFX1380 SERIES PFX1380 Man 1 2009...

Page 2: ...ed keep free of dust lint hair or anything that may reduce air flow 7 Keep hair loose clothing fingers and all parts of body away from openings and moving parts 8 DO NOT pick up anything that is smoki...

Page 3: ...rounding conductor and grounding plug The pigtails must be inserted into an appropriate 12 gauge 3 prong extension cord This unit is for use on a nominal 120 volt circuit and has a grounded plug that...

Page 4: ...to a separate and grounded 20 amp wall socket circuits when this is accomplished the green indicator light will be lit on heated models 4 Attach the hose system to the unit and to your carpet wand 5 T...

Page 5: ...open 8 At the end of each day run the vacuum for 3 minutes with lid open and filter off Safety Precautions These precautions are designed with the safety of the operator the equipment and others in m...

Page 6: ...se recommended for steam type extraction equipment The use of any chemicals with abrasive additives voids the warranty 5 Do not use any replacement parts except those specified on the parts list Perfo...

Page 7: ...tive Cover 18 X8102 Neon Light w Lens Orange For Heater Units only 19 72387A Screw 8 x 5 8 black Tap phil pan 20 PX86 Indicator Light Green 250V For Heater units only 71804A Plug 1 2 Black Nylon For P...

Page 8: ...8 MODEL PFX1380 SERIES CARPET EXTRACTOR PARTS PFX1380 base assembly...

Page 9: ...ong 7 72640A gasket vac manifold long 8 72623A cover vacuum manifold long 9 7CW002 screw 6 x 3 4 phil pan ts type a 18 8 ss 10 72000A rod 3 16 x 5 1 2 all thread stud 18 8 ss 11 72657A screw 10 24 x 4...

Page 10: ...tly out of 3 Bend screen by round squeezing slightly by hand until there is an obvious space between ball and inside of screen Foam dirty solution 1 Foam from carpet by 1 Use additional coming out of...

Page 11: ......

Page 12: ...other instructions for a period of 5 years from date of purchase on housings and frame 3 years on heater 1 year on pump vac motor and parts and workmanship In case you as our customer meet any trouble...