Chapter 4 Panel and keyboard display and operation
ADSD-S-S
33
8. The encoder input signal [Note8].
Digital tube lines said a state, up the vertical bar stroke means high level, or means low level.
9.
Rotor absolutely position [Note9]
Said in a turn, the rotor relative to stator at the position, as a turn to a cycle, encoder pulse unit,
as the encoder Z pulse to origin. For example, to use 2500 line encoder, its range is 0 ~ 9999, as the
Z pulse appeared values to 0.
10.
Control mode [Note10]
The first three characters said control mode, the last character said gain combination.
11.
Alarm code [Note11]
No alarm shows two minus signs. Have alarm displaying alarming number and flickering.
When come up alarm ,the display will automatically into state monitor and display alarming code,
but you can through the keyboard to do other operations, when the state is not monitored, while the
most right side digital decimal point of the tube twinkle said there are warning.
4-4 Parameter setting
The parameters used ten parameters to show, the
hundreds
is segment code, ten and unit's
digit is parameter code. For example, parameter L102, segment code is "1", the parameters code is
"02," the display shows "L-102".
Under the main menu to choose the parameters setting "L-",pressing
key into the
parameters setting mode .The first ,using
、
key to choice section ,then ,pressing
key to
choice segment code. After ,using
、
key to choose segment code ,then pressing
to
display the parameters .
Chapter 4 Panel and keyboard display and operation
ADSD-S-S
34
Using
、
key to change the parameters number. Press
or
once, parameters
increase or decrease 1, after the changed finished, press
key returned to parameters selection
state. If the modified numerical don't satisfied, not pressing
key to make sure, can press
key
canceled, the parameters was restored original value.
Modification of the parameters was not saved to EEPROM, if need permanently saved,
please use the parameters of the management to write operation. Parameters section and parameters
code are not necessarily continuous, the unused parameters segments and parameters code will be
skipped and won’t be chosen.
P a r a m e t e r s v a l u e i n c r e a s e
P a r a m e t e r s v a l u e d e c r e a s e
Update Acknowledge
P a r a m e t e r s s e g m e n t s
i n c r e a s e a n d d e c r e a s e
P a r a m e t e r s c o d e
i n c r e a s e a n d d e c r e a s e
Parameters value
4-5 Parameter management
The management of the main parameters between processing parameter table and EEPROM
operation, in the main menu to choice parameters management“
”, press
key into parameters
management mode.
There are three kinds of operation mode to chance by the
、
key. After the change
press
key until 3 second, to activate operation. Then after can press
key returned to
parameters selection state.