Section I Safety Precautions 

Please read the manual before the installation, operation and inspection of 

the product. For the safe operation, remind  you  to  pay special  attention to the 
“Warning” and “Attention” in the manual. 

*Attention

 

The potential danger will lead to slight or medium life harm or 

equipment damage. It could also warn the violate operation.

 

 

Warning

 

The potential danger could lead to life harm or private loss! 

Statement:

  When  the  brake  unit  is  used  with  other  brand 

frequency  inverter  together,  our  company  is  only  undertake  the 
product  quality  problems  of  3  packets  of  responsibility;  If  the 
customer  need  other  projects  of  joint  liability  guarantee,  Please   
cover insurance of the related domestic property insurance company 
yourself,  In  order  to  obtain  relatively  good  liability  to  pay 
compensation. 

*Attention

 

 

*Attention

 

● 

Do  not  use  any  brake  unit  and  brake  resistor  lack  of  or  with 
damaged spares.

 

● 

Do not touch the internal spares for there are CMOS spares on the 
control  card  of  the  brake  unit.  Otherwise  it  will  damage  the 
spares. 

● 

Please  add  the  fan  or  other  cooling  equipment  when  multiple 
brake units installed parallel in the one cabinet.   

Summary of Contents for PB6012

Page 1: ...sis and remove and how to select brake resistor etc The manual can be used for system designer reference In order to ensure correct installation and operation of the frequency converter please careful...

Page 2: ...spection 4 Section III Installation 5 Section IV Function Parameter Description 8 Section V Single Unit Running 9 Section VI Paralleled running 11 Section VII Fault Diagnosis and Solutions 13 Section...

Page 3: ...nd frequency inverter together our company is only undertake the product quality problems of 3 packets of responsibility If the customer need other projects of joint liability guarantee Please cover i...

Page 4: ...current inside Do not touch the heat sink of the brake unit and the brake resistors otherwise it will lead to scald or electric shock There is high temperature and heated spares inside after the brak...

Page 5: ...e unit could be adjusted and repaired During the running do not touch any spares inside Please refer to the content in the manual when analyze and manage the fault of the brake unit Any modification t...

Page 6: ...and type of the product complies with the order Please contact the supplier of Powtran products if any problems are found Only the well trained personnel are allowed to use this unit and such personn...

Page 7: ...ve 50 2 Preventing electromagnetic interference away from the interference so urces 3 Prevent dropping dust powder cotton fiber or fine metal powder from entering it 4 Prevent oil salt and corrosive g...

Page 8: ...Section III Installation 6 B PB6022 PB6024 C PB6032 PB6034 3 3 Main circuit specification...

Page 9: ...raking resistor Rb and brake unit is less than 10 m and must use heat resisting conductors 3 P N is the terminal of the frequency inverter dc bus P is the positive terminal e N is a negative terminal...

Page 10: ...rmal running and damage Description of control circuit terminal of the brake unit Terminal Specification Note Parameter Setting switch 1 Slave and host selection switch when M is ON the brake unit is...

Page 11: ...run it 200V grade Voltage selection the input power supply voltage of the frequency inverter Brake starting voltage PN voltage 220V 220VAC 365VDC 3 400V grade Voltage selection the input power supply...

Page 12: ...Single Unit running 10 2 please confirm starting braking voltage macth the device Warning in the CHARGE indicating lamp before fully extinguished there is voltage between PN not allowed to adjust the...

Page 13: ...he factory setting of the brake unit is set to be the host M do not modify the factory setting if only one brake unit is used 2 When 2 or more over brake units are paralleled the control terminal S is...

Page 14: ...Section VI Paralleled running 12 brake unit 3 Etc Note Double wind the M1 M2 and S1 S2 and please make it as short as you can the maximum paralleled brake units is only 10...

Page 15: ...nit 2 Inverter OU Lack of braking of the brake resistor check the brake condition Not suited brake unit voltage braking unit voltage too high Brake unit faulted Change brake unit 3 relay action over h...

Page 16: ...PB6022 B 70A PB6032 B 140A 400V level 380 415V Type Sharp size Allowed max brake current 65 PB6014 A 40A PB6024 B 70A PB6034 B 140A NOTE The allowed maximum current of the power spares IGBT inside th...

Page 17: ...1 5 6000W 1 60 45 PB6032 1 3 4 9600W 1 75 55 1 3 4 9600W 1 100 75 PB6032 2 5 6000W 2 125 93 PB6032 3 5 6000W 3 150 110 3 5 6000W 3 8 4 400V specification and selection reference Capacity no HP kW Bra...

Page 18: ...e inductance 2 Braking resistor grounded is strictly prohibited otherwise it will lead the serious damage to the unit and inverter 3 Selection of the brake resistor capacity is for reference it depend...

Page 19: ...2 Users without permission to repair or alteration caused by product failure 2 3 Users beyond the standard specifications require the use of the inverter caused by product failure 2 4 Users to buy and...

Reviews: