Chapter 5 Function parameter
39
Ch
ap
ter 5
211.
F7.08 Acceleration time 2
0.0s to 6500.0s
Depends
on models
☆
212.
F7.09 Deceleration time 2
0.0s to 6500.0s
Depends
on models
☆
213.
F7.10 Acceleration time 3
0.0s to 6500.0s
Depends
on models
☆
214.
F7.11 Deceleration time 3
0.0s to 6500.0s
Depends
on models
☆
215.
F7.12 Acceleration time 4
0.0s to 6500.0s
Depends
on models
☆
216.
F7.13 Deceleration time 4
0.0s to 6500.0s
Depends
on models
☆
217.
F7.14
Switching frequency point
between acceleration time 1
and acceleration time 2
0.00Hz to F0.19 (maximum
frequency)
0.00Hz
☆
218.
F7.15
Switching frequency point
between deceleration time 1
and deceleration time 2
0.00Hz to F0.19 (maximum
frequency)
0.00Hz
☆
219.
F7.16
Forward/reverse rotation
deadband
0.00s to 3600.0s
0.00s
☆
220.
F7.17 Reverse rotation control
0: Enable 1: Disable
0
☆
221.
F7.18
Set frequency lower than
lower limit frequency mode
0: running at lower limit frequency
1: stop
2: zero speed running
0
☆
222.
F7.19 Droop control
0.00Hz to 10.00Hz
0.00Hz
☆
223.
F7.20
Setting cumulative power-
on arrival time
0h to 36000h
0h
☆
224.
F7.21
Setting cumulative running
arrival time
0h to 36000h
0h
☆
225.
F7.22 Start protection selection
0: OFF 1: ON
0
☆
226.
F7.23
Frequency detection value
(FDT1)
0.00Hz to F0.19(maximum
frequency)
50.00Hz
☆
227.
F7.24
Frequency detection
hysteresis value (FDT1)
0.0% to 100.0% (FDT1 level)
5.0%
☆
228.
F7.25
Frequency reaches
detection width
0.00 to 100% (maximum frequency)
0.0%
☆
229.
F7.26
Frequency detection value
(FDT2)
0.00Hz to F0.19 (maximum frequency)
50.00Hz
☆
230.
F7.27
Frequency detection
hysteresis value (FDT2)
0.0% to 100.0% (FDT2 level)
5.0%
☆
231.
F7.28 Random arrivals
0.00Hz to F0.19 (maximum
50.00Hz
☆