17
13.3 - ‘FOT’ closing cycle photoelectric sensor
WARNING
The control board only starts the closing movement when this
sensor is already working properly.
Use only Miller Edge 4-wire pulsed sensors to comply with UL325
13.4 - ‘FEC’ opening cycle photoelectric sensor
WARNING
The control board only starts the opening movement when this
sensor is already working properly.
If the gate opening movement does not generate any entrapment
situation, it is possible to disable the input for the open sensor
(see topic 16.3 "TRV").
Use only Miller Edge 4-wire pulsed sensors to comply with UL325
IMPORTANT
For proper operation it is important to
connect the enclosure of the sensors
(photoelectric receiver side) to the
chassis ground of the operator.
WARNING
The logic controller supplies 15V (maximum
120 mA direct current) to power photocells and
receivers and IT DOES NOT HAVE OVERCURRENT
PROTECTION. In case the equipment need
a higher voltage or current, a further power
supply must be used.