8 - PRECAUTIONS FOR ELECTRICAL INSTALLATION
To avoid damage to wiring, it is important that all conduits are properly fixed to the operator. The passage of the wiring must be made
through conduits, internally to floor base, ensuring that no wiring conductor is trapped or damaged.
A conduit of 3/4"in diameter must be installed between the power distribution box and the total disconnect device inside the concrete
base.
Install conduits for the 120 Vac.
Main power supply MUST run in separated conduits.
The conduit may be limited to 1/2 "in diameter for external devices like pushbuttons or sensors.
All conduits must be UL approved.
9 - INSTALLING AND FIXING THE OPERATOR
Equipment dimensions: Model DZ PREDIAL Models DZ CONDOMINIUM and DZ 1500
14.01 in
11.57 in
6.14 in
8.35 in
12.28 in
7.99 in
6.18 in
12.64 in