5
TOOLS REQUIRED FOR INSTALLATION
Here are some tools required to install the operator:
ELECTRICAL INSTALLATION
For electrical installation, the network shall contain the following characteristics:
- Electric network 127V or 220V;
- Have 5A circuit breakers in the electrical distribution box;
- 3/4 "diameter conduit between the electrical distribution box and the total
disconnect device;
- 3/4 "diameter conduit between the total shut-off device and the operator
connection point;
- 1/2 "diameter conduits for buttonhole, external and optional;
- 1/2 "diameter for safety photocells (optional).
PLIERS
SAWING BOW
SOCKET WRENCH
SCREWDRIVER
NUT WRENCH
LADDER
WELDING MACHINE
HAMMER
LEVEL
TAPE MEASURE
FRAME
DRILL
PENCIL
SANDER
- The cable for the fixed wiring must comply with NBR NM 247-3;
-The power conductor of a product for internal use must be a
flexible cable 3 x 0.75 mm²; 500 V, according to the norm NBR
NM 247-5;
-The power conductor of a product for external use must be a
3 x 0.75 mm² flexible cable; 500 V, according to IEC 60245-57.