background image

4

5

Motor power supply

Cable type and size

110V

1 PP cable - 2 x 2.5 mm

220V

1 PP cable - 2 x 2.5 mm

220V

1 PP three-phase cable - 3 x 2.5 mm

380V

1 PP three-phase cable - 4 x 2.5 mm

 

NOTE:

 If accessories are used, provide piping and cables as needed. 

Provide a grounding rod that will be fixed close to the body of the gate.

GENERAL FEATURES

• 

Universal cabinet that allows installing the barrier arm on either side of 

the barrier.

• 

Concealing system for manual unlocking (up to 4.5m).

• 

Electronic control unit with frequency inverter.

• 

Mechanical stop with height adjustment.

• 

System activation through a gearmotor, pulleys, and belts.

• 

Galvanized steel cabinet with anti-corrosion treatment and electrostatic 

painting guarantee excellent resistance against the action of time.

• 

Limit switch system with encoder.

• 

Electronic brake.

• 

Allows  installing  several  accessories  (inductive  loop,  signal  light, 

photocell, pushbutton, etc.).

TECHNICAL SPECIFICATIONS

Non-stop barrier (linear)

Barrier length

Cycles/hour

Opening 

time 

(adjustable)

Closing

time 

(adjustable)

Voltage

Gearbox

2.5 to 3m

1200

0.7 second

(minimum)

0.7 second 

(minimum)

127 and 

220 V

Oil bath 

method 

Non-stop barrier (articulated)

Barrier length Cycles/hour

Opening 

time 

(adjustable)

Closing

time 

(adjustable)

Voltage Gearbox

Barrier profile

3m (maximum) 580

0.7 second

(minimum)

0.7 second         

(minimum)

127 and

220 V

Oil bath 

method

Rectangular

60 x 30mm

EQUIPMENT DIMENSIONS

FR

ONT
 OF

 THE
 BARRIER

INSPECTION

 DOOR

Summary of Contents for JETFLEX

Page 1: ...Technical Manual P31493 08 2022 Rev 0 All images in this manual are for illustrative purposes only Manufactured by Motoppar Ind stria e Com rcio de Automatizadores Ltda Av Dr Labieno da Costa Machado...

Page 2: ...installed Notice the need for optional accessories Calculate the flow of vehicles on site NOTE If the floor does not meet the above specifications a concrete base plate respecting the cabinet base dim...

Page 3: ...lts Galvanized steel cabinet with anti corrosion treatment and electrostatic painting guarantee excellent resistance against the action of time Limit switch system with encoder Electronic brake Allows...

Page 4: ...ehicles according to the suggested dimensions Cover Barrier Base Articulated barrier profile EXTRA 180 mm USEFUL LENGTH BARRIER LENGTH 180 mm BARRIER LENGTH 110 mm Ground clearance Barrier fixing dedu...

Page 5: ...previously marked locations OBS Make 04 holes with a 10mm drill and at least 80 mm deep 4 Insert the anchor bolts in the holes of the base as shown below OBS The anchor bolts must not be inserted thor...

Page 6: ...ires Use a dedicated circuit breaker that is a circuit breaker where only the barrier will be connected 11 Check setthebarrieralignment openingandclosing Usemechanical stops for this situation and mov...

Page 7: ...nsioned and ready for operation With your thumb apply even pressure on the belt If it does not bend it is because it is well tensioned If the belt is loose adjust it through the belt tensioner screws...

Page 8: ...drives the three phase induction motor from a single phase AC power supply and a logic controller to carry out the inverter operations For more information refer to the TRIFLEX CONNECT AC control uni...

Reviews: