background image

6

7

OBS:

 Measurements in mm. The base plate must be leveled to allow the 

equipment to perform better.

INSTALLING THE BARRIER

1.  When fixing the barrier, notice that the cabinet inspection door must 

face the side of the road or vehicle passage.

76 mm (3")

 BUILDING THE BASE PLATE TO INSTALL THE

CABINET

Build a concrete base so that the highlighted direction (350) faces the curb 

(street, passing vehicles) according to the suggested dimensions.

Cover 

Barrier Base

Articulated barrier profile

(EXTRA) 180 mm

USEFUL LENGTH = BARRIER LENGTH -180 mm

(BARRIER 110 mm)

(Ground clearance)

Barrier fixing deduction 283 mm

Useful length = Barrier length -283 mm

Barrier length

¾” CONDUIT PIPE 

(MINIMUM) FOR THE 

CABLES POSITIONED IN 

THE CENTER OF THE BASE 

INSPECTION DOOR

VEHICLE P

ASSAGE

Linear barrier profile

CURB USEFUL HEIGHT

210 (OPENING DEDUCTION)

30 (SAFET

Y MAR

GIN)

OPEN BARRIER HEIGHT

DIST

ANCE FR

OM BARRIER BASE T

O C

O

VER

GR

OUND CLEARANCE A

T BARRIER BASE

(FIXING – DEDUCT FROM THE BARRIER LENGTH 280 mm)

Summary of Contents for JETFLEX

Page 1: ...Technical Manual P31493 08 2022 Rev 0 All images in this manual are for illustrative purposes only Manufactured by Motoppar Ind stria e Com rcio de Automatizadores Ltda Av Dr Labieno da Costa Machado...

Page 2: ...installed Notice the need for optional accessories Calculate the flow of vehicles on site NOTE If the floor does not meet the above specifications a concrete base plate respecting the cabinet base dim...

Page 3: ...lts Galvanized steel cabinet with anti corrosion treatment and electrostatic painting guarantee excellent resistance against the action of time Limit switch system with encoder Electronic brake Allows...

Page 4: ...ehicles according to the suggested dimensions Cover Barrier Base Articulated barrier profile EXTRA 180 mm USEFUL LENGTH BARRIER LENGTH 180 mm BARRIER LENGTH 110 mm Ground clearance Barrier fixing dedu...

Page 5: ...previously marked locations OBS Make 04 holes with a 10mm drill and at least 80 mm deep 4 Insert the anchor bolts in the holes of the base as shown below OBS The anchor bolts must not be inserted thor...

Page 6: ...ires Use a dedicated circuit breaker that is a circuit breaker where only the barrier will be connected 11 Check setthebarrieralignment openingandclosing Usemechanical stops for this situation and mov...

Page 7: ...nsioned and ready for operation With your thumb apply even pressure on the belt If it does not bend it is because it is well tensioned If the belt is loose adjust it through the belt tensioner screws...

Page 8: ...drives the three phase induction motor from a single phase AC power supply and a logic controller to carry out the inverter operations For more information refer to the TRIFLEX CONNECT AC control uni...

Reviews: