12
The
[FLUID LEVEL]
button/indicator reads [
OK
]
when there is sufficient fluid in
the overflow (front) tank. Should the level drop too low, the indicator will turn red
and flash the word [
ADD
]. After adding a quantity of fluid at the correct dilution to
the front tank, depress the indicator to reset it to [
OK
].
NOTE
: If the machine has just been filled, it might be necessary to depress the
[
FLUID LEVEL
] indicator to clear the [
ADD
] indication.
The
[PUMPS]
switch is provided to control the pumps. After initially filling the
machine, and clearing the [
ADD
] indication as described above, the [
PUMPS
]
switch should be turned on (indicated by the numeral
[1]
) to begin circulation. If the
machine is expected to be idle for long periods, the pumps can be turned off to save
evaporative loss of fluid, save energy, and reduce wear and tear on the equipment.
See also Section
III.6
for information on the Shutdown Timer.
The [
MAIN FILTER
] indicator shows the state of the main filter, the long housing
on the left. If it is displays [
CHANGE
] the filter cartridge should be replaced. This
condition does not prevent operation. The state of this indicator is controlled by
pressure switch
PS1
. The indicator will not be visible if the pumps are not running.
The [
OVRFLO FILT
] (Overflow Filter) indicator shows the state of the overflow
tank’s filter, the long housing on the right. If it is displays [
CHANGE
] the filter
cartridge should be replaced. This condition does not prevent operation. The state
of this indicator is controlled by pressure switch
PS2
. The indicator will not be
visible if the pumps are not running.
The
[AUTO CYCLE]
button enables and disables the Automatic mode of the
machine. To run automatic cycles, this button must read
[ENABLED]
. When
automatic cycles are not enabled, this button will flash the word
[DISABLED]
.
The
[READY]
indicator indicates if the cleaner is ready to run automatic cycles.
For this indicator to be on, the following conditions must be met:
1.
The [
PUMPS
] switch must be ON
[1]
(but the pumps might not be
running.)
2.
The [
FLUID LEVEL
] indicator must show [
OK
].
3.
The [
AUTO CYCLE
] function must show [
ENABLED
].
If these conditions are not all present, the indicator will display [
NOT READY
].