background image

O

UTDOOR ENCLOSURE TYPE 

MINI

 HANDBOOK

  

 

4

 

Introduction 

The  Outdoor  Enclosure  type  MINI  (ODE-MINI),  is  a  cost-effective  weatherproof  enclosure  for 

ViaLiteHD

 

systems and associated hardware. It is intended to service the requirements of most GPS timing and satellite 
communication systems though can be configured to suit a wide range of other applications. 
 
The ODE-MINI system is comprised of the following key parts:  

 

IP-65 rated external enclosure fitted with: 

 

Dual power supplies (redundancy or power sharing) 

 

Capacity for up to two 

ViaLiteHD

 OEM modules with front panel connections 

 

Termination of input power cable (inside the supplied quick release latching connector) 

 

Patch box for termination of optical cable (various quad fibre cable lengths available) 

 

Connectorised RF inputs / outputs. 

 
It has a wide range of optional accessories including: 

 

Lightning suppressor(s) 

 

Optical cable 

 

Wall or pole mount fixings. 
 

ViaLiteHD

  RF  Fibre  Optic  Links  (FOLs)  are  a  family  of  fibre  optically  coupled  link  systems  designed  for  the 

transmission of RF analogue signals over long distances for the communications market.   
 

ViaLite

 is a product brand manufactured by Pulse Power and Measurement Ltd (PPM). 

ViaLite Communications 

is a division of

 

Pulse Power and Measurement Ltd (PPM). 

 

1.1 

Typical deployment 

A typical system operates as follows. 
 
The  ODE-MINI  would  house  a  set  of  FOL  TX  modules,  in  a  remote  outdoor  location  connected  to  antenna 
equipment.    Antenna  electrical  signals  are  input  to  the  transmitter  modules,  which  contain  RF  signal 
conditioning  and  laser  control  circuitry.    The  modules  modulate  the  intensity  of  a  beam  of  light  with  the  RF 
signal for optical transport over a fibre optic cable. 
 
The  light  travels  through  the  optical  fibres  to  corresponding  receiver  modules.    The  distance  between 
transmitter and receiver can range from 1 m to 100 km; distance in excess of 100 km can be achieved  with 
more complex optical transport systems, depending on the system specified. 
 
The  receiver  module  converts  the  modulated  light  back  into  an  electrical  signal,  which  is  available  at  its 
output. 

1.2 

ViaLiteHD compatibility 

The RF and optical interfaces are compatible with all 

ViaLiteHD

 Blue modules.   

 
 
Contact 

ViaLite Communications

 or your local 

ViaLite 

agent for more details.   

 
 

1.3 

Care of fibre optic connectors 

When  the  fibre  optic  cables  are  not  connected,  it  is  essential  that  the  cable  and  equipment  connectors  are 
protected by the dust caps provided with the system.  Failure to do so may result in damage to the fibre ends, 
which are critical to the system performance.  Please refer to section 1.4 for fibre optic cable handling details. 
 

Summary of Contents for ViaLite MINI

Page 1: ...pe MINI ODE MINI User Guide HMA HB 2 CR4552 21 12 2020 Pulse Power Measurement Ltd 65 Shrivenham Hundred Business Park Watchfield Swindon Wiltshire SN68TY UK Tel 44 0 1793 784389 Email sales vialite com Web www vialite com ...

Page 2: ... ESD Precautions Precautions for handling electro static sensitive devices should be observed when handling all ViaLite modules Technicians should ensure that they use effective personal grounding i e ESD wrist strap etc when servicing the equipment Any equipment or tools used should be grounded to prevent static charge build up Good practice should be observed at all times For reference see relev...

Page 3: ... 7 2 1 ODE MINI external features 7 Humidity control ventilator gland 7 2 2 Weatherproof interface connections 8 2 3 Mounting the ODE MINI 9 Using the 70004 2 wall mounting bracket kit 9 Using the 70004 60MINI 90MINI 110MINI pole mounting kit 9 2 4 Lightning Suppressor 10 2 5 Antennas 11 2 6 Termination of RF Connections 11 2 7 Termination of power 13 2 8 Termination of Optical fibre 14 2 9 LNB Vo...

Page 4: ...division of Pulse Power and Measurement Ltd PPM 1 1 Typical deployment A typical system operates as follows The ODE MINI would house a set of FOL TX modules in a remote outdoor location connected to antenna equipment Antenna electrical signals are input to the transmitter modules which contain RF signal conditioning and laser control circuitry The modules modulate the intensity of a beam of light ...

Page 5: ...e cleaned before use even where they have been protected with dust caps A large percentage of performance issues can be attributed to dirty fibres For more details please read the cleaning instruction which accompanies the connector cleaning kit Cleaning optical connectors high levels of contamination If there are performance issues that are not resolved by basic cleaning in section 1 4 3 then the...

Page 6: ...t there is no optical radiation being emitted by the fibre Remove all power sources to all modules and completely disconnect the optical fibres SC APC Connectors To connect SC APC optical connectors follow these steps Remove the plug protective cover Align the connector keyway slot in the adaptor to the key of the plug Gently push the plug into the adapter until a click is heard and the connector ...

Page 7: ... advisable for any application where there may be significant solar gain 70002 MINI Wall mount plate for 75010 Outdoor Enclosure Kit Fixings 70004 XXXMINI Pole mounting kit pole diameter XXX diameters range from 15 168 mm 27520 Lightning Suppressor Kit for Outdoor Enclosure 1 required per RF Channel Humidity control ventilator gland The enclosure incorporates a side mounted vent that allows the ai...

Page 8: ...eatherproof interface connections To maintain the enclosure s IP rating you should observe the following The front door should be closed and screws tightened All glands should be compressed on to either a cable or blanking rod All connectors should be mated to either a matching half or suitable sealing dust cap ...

Page 9: ...closure follow these steps Mount the long length of unistrut centrally to the top of the ODE MINI using the supplied washers and screws small Mount the short length of unistrut centrally to the bottom of the ODE MINI using the supplied washers and screws small Slide one unistrut nut into the top and one into the bottom Wrap the pole with the pipe grommet in the top position Slide one end of the cl...

Page 10: ...ressor has a grounding fixing M8 on the suppressor this should be used to achieve maximum protection The standard options are 27520 Lightning Suppressor Kit for Outdoor Enclosure 1 required per RF Channel When fitting a lightning suppressor first fit the 0 5 m cable to the N Type on the ODE MINI Fit the N Type adaptor to the cable Then fit the lightning suppressor to the adaptor on the cable Light...

Page 11: ...ectors are fitted you MUST ensure that both halves are the same impedance mating dissimilar connectors will cause permanent physical damage RF inputs and outputs should not be exposed to DC voltage levels in excess of 36 V Absolute maximum no damage RF input level is nominally 13 dBm some units may tolerate more power please see module handbook Some transmitter modules are pre configured to have a...

Page 12: ... be sensitive to large transients 5V applied to either input or output This may result in permanent damage to the units particularly to low frequency units Some receiver modules are equipped with DC loads on their outputs please see the module handbook Contact ViaLite Communications for more details ...

Page 13: ... Power Connector Mains 20A Socket Cable Mount 250 V ac Polyamide This equipment must be earthed in accordance with the local codes Incomplete or incorrect earthing will cause a safety hazard The incoming power cable must have a diameter between 6 and 12 mm to be correctly retained by the connector The electrical conductor cross sectional area should be within the range of 1 2 5 mm2 to ensure suffi...

Page 14: ...resents SC APC connections to the end user within the patch box as shown in the picture below Options to terminate in LC APC or FC APC are available A kit of additional parts and adapters is supplied with the patch box to allow the customer to tailor their installation on site A B 1 a 2 b QUAD IDENTS A Module 2 B Module 1 a SFP 1 b SFP 2 Feed from ODE MINI Feed from external site ...

Page 15: ...m 6 Module 2 is usually RX Connect RJ45 and interrogate the site controller to confirm part numbers serial numbers and settings gain etc If using a standard ODE MINI at both ends of the link you must ensure your Neutrik cable is a crossover with the module ports 1 and 2 crossed over and the SFP ports 1 and 2 crossed over 2 9 LNB Voltage selection ViaLiteHD Blue modules have the option to pass a vo...

Page 16: ... which is labelled internally To drive external equipment with very high power requirements e g a BUC the option for dual redundant power supplies can be substituted for a dedicated supply to provide this function which bypasses this selector See next section ODE MINI power supplies for details The ODE MINI LNB voltage setting is factory set to match the customer requirement prior to shipping but ...

Page 17: ...h identical modules in the left hand LH and right hand RH positions It can optionally be equipped with either just a single main PSU module LH or with a main PSU LH and LNA BUC PSU RH The voltage inputs for the various power supplies options have the following requirements AC input wide range 88 264 VAC 47 63 Hz Power supply LPS MINI DC input 18 75 VDC Power supply LPS MINI DC 2 12 Replacement of ...

Page 18: ... is used in all AC 48 Vdc and 24 Vdc powered units unless otherwise advised To replace the fuse the procedure is as follows First isolate the unit from the mains power inlet by unplugging the mains power lead Unscrew the fuse holder by hand Remove the failed fuse from the fuse holder and replace with your new fuse Screw the fuse holder back together Apply power by switching the power isolation swi...

Page 19: ...ng shall be as stated in document F292 PPM Manufactured Product Warranty which is available at https ppm co uk warranty periods Extended warranty options are available at the time of purchase Prior to returning any goods for warranty or non warranty repairs please contact PPM ViaLite Communications for a returns reference ...

Page 20: ...is equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense PULSE POWER MEASUREMENT LTD 2...

Reviews: