5.3.1
Redundancy load module, plug-in card
The redundancy load module does not have a microprocessor, I2C bus or an alarm line. It will not be recognised by the ViaLiteHD SNMP
and web controller or included in the GUI. The alarm line of the module is resistively pulled down.
The
ViaLiteHD
Redundancy load module may have hot surfaces when operating under full load. Suitable precaution should be taken when
handling this device, see safety instructions.
5.3.2
Redundancy load module, front panel
The redundancy load plug-in module has two front panel LEDs for indication of the state of the module.
The following table shows the operation
Colour
SNMP and Web controller
LED1
GREEN
Normal
No light
No power
LED2
GREEN
LOAD ON (Any load resistor active)
No light
LOAD OFF
5.3.3
Redundancy load module, DIP switches
The
ViaLiteHD
Redundancy load module has one four way DIP switch (SW5) that configures the load.
The switch is on the rear side of the module and can be accessed with the module partially withdrawn.
SW5
Name
OFF
ON
Position 1
Load 1
Load resistor OFF
Load resistor ON
Position 2
Load 2
Load resistor OFF
Load resistor ON
Position 3
Load 3
Load resistor OFF
Load resistor ON
Position 4
Load 4
Load resistor OFF
Load resistor ON
LED1
LED2
DIP switch (SW5)