1 4#
+#+-07
2SP
1 4#
*- !
+#+
1#23.
2SP
+#+
!'1.
" *
1'+
. 11
* ,%
!'1.
1#23.
2SP
"-,20
2SP
*'%&2
2SP
4 *4#
2SP]
-32
*',#
2SP
2 %
-32
" *
1#23.
2SP
7#1
" **-
2SP
7#1
,-
2SP
,-
7#1
" *&'
2SP
7#1
,-
2SP
,-
7#1
31#" *
2SP
7#1
,-
1'+
1#23.
2SP
7#1
#,1'+
2SP
7#1
,-
2SP
,-
0#*1'+
2SP
* ,%
1#23.
2SP
3)
* ,%3
2SP
!#!)
#1$0
'21#
3)
. 11
1#23.
2SP
7#1
#,. 11
2SP
7#1
,-
,#5. 1
2SP
7#1
#,$ 12
2SP
7#1
,-
2.0
,-
50
51
[01]
[02]
[03]
[04]
[05]
[06]
[07]
[08]
[09]
[10]
[11]
[12]
[13]
[14]
[15]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[24]
[25]
[26]
[27]
[28]
[29]
[30]
[31]
[32]
[33]
[34]
[36]
[37]
[38]
[39]
[41]
[42]
[43]
[44]
[45]
[46]
[47]
[48]
[49]
[50]
[51]
[52]
[53]
[54]
[55]
[56]
[57]
[58]
[59]
[60]
[61]
[62]
Set correct password
Enter advanced setup menu?
Select temperature input
Select potentiometer input
Select linear resistance input
Select current input
Select voltage input
Select 0.0-1 V input range
Select 0.2-1 V input range
Select 0-5 V input range
Select 1-5 V input range
Select 0-10 V input range
Select 2-10 V input range
Select 0-20 mA input range
Select 4-20 mA input range
Select 2-wire sensor connection
Select 3-wire sensor connection
Select 4-wire sensor connection
Set resistance value low
Set resistance value high
Select Celsius as temperature unit
Select Fahrenheit as temperature unit
Select TC sensor type
Select Ni sensor type
Select Pt sensor type
Select display unit
Select decimal point position
Set display range low
Set display range high
Set relays in % of input range
Set relays in display units
Select Pt10 as sensor type
Select Pt20 as sensor type
Select Pt50 as sensor type
Select Pt100 as sensor type
Select Pt200 as sensor type
Select Pt250 as sensor type
Select Pt300 as sensor type
Select Pt400 as sensor type
Select Pt500 as sensor type
Select Pt1000 as sensor type
Select Ni50 as sensor type
Select Ni100 as sensor type
Select Ni120 as sensor type
Select Ni1000 as sensor type
Select TC-B as sensor type
Select TC-E as sensor type
Select TC-J as sensor type
Select TC-K as sensor type
Select TC-L as sensor type
Select TC-N as sensor type
Select TC-R as sensor type
Select TC-S as sensor type
Select TC-T as sensor type
Select TC-U as sensor type
Select TC-W3 as sensor type
Select TC-W5 as sensor type
Select TC-Lr as sensor type
Select OFF function - relay is permanently off
Select POWER function - relay indicates power status OK
Select ERROR function - relay indicates sensor error only
Select WINDOW function - relay controlled by 2 setpoints
Select SETPOINT function - relay controlled by 1 setpoint
Select Normally Closed contact
Select Normally Open contact
Set relay setpoint
Activate relay on decreasing signal
Activate relay on increasing signal
Set relay hysteresis
SCROLLING HELP TEXT IN DISPLAY LINE 3
No error action - undefined status at error
Open relay contact at error
Close relay contact at error
Hold relay status at error
Set relay ON delay in seconds
Set relay OFF delay in seconds
Relay contact is Closed Inside Window
Relay contact is Open Inside Window
Set relay window setpoint high
Set relay window setpoint low
Set relay window hysteresis
No error action - undefined status at error
Open relay contact at error
Close relay contact at error
Hold relay status at error
Set relay ON delay in seconds
Set relay OFF delay in seconds
Open relay contact at error
Close relay contact at error
Select current as analogue output type
Select voltage as analogue output type
Select 0-20 mA output range
Select 4-20 mA output range
Select 20-0 mA output range
Select 20-4 mA output range
Select no error action - output undefined at error
Select downscale at error
Select NAMUR NE43 downscale at error
Select NAMUR NE43 upscale at error
Select 0.0-1 V output range
Select 0.2-1 V output range
Select 0-5 V output range
Select 1-5 V output range
Select 0-10 V output range
Select 2-10 V output range
Select 1-0.0 V output range
Select 1-0.2 V output range
Select 5-0 V output range
Select 5-1 V output range
Select 10-0 V output range
Select 10-2 V output range
Set temperature for analogue output low
Set temperature for analogue output high
Enter password setup
Enter simulation mode
Perform process calibration
Enter display setup
Perform memory operations
Load saved configuration into 4116
Save 4116 configuration in 4501
Adjust LCD contrast
Adjust LCD backlight
Write a 6-character device TAG
Analogue output value is shown in display line 3
Device TAG is shown in display line 3
Calibrate input low to process value?
Calibrate input high to process value?
Enable simulation mode?
Set the input simulation value
Relay simulation - use
and
to toggle relay 1
and 2
Enable password protection?
Set new password
Enable Fastset functionality?
Relay setpoint - press
to save
Relay setpoint - Read only
Select language
Use process calibration values?
Set value for low calibration point
Set value for high calibration point
ROUTING DIAGRAM
Advanced settings (ADV.SET)
To default state 1.0
2.0 In the submenu simulation (SIM) you must
press
to return to the default state 1.0.