10
9106 - Product Version 9106-001
Accuracy, the greater of general and basic values:
Auxiliary supplies:
2-wire supplies (terminal 44...43 and 54...53)
9106B1x (U
o
=28 VDC) ......................... 23...16 V / 0...20 mA
9106B2x (U
o
=25.6 VDC) ...................... 21...14.8 V / 0...20 mA
Wire size (max.) ........................................... 0.13...2.08 mm
2
/ AWG 26...14
stranded wire
Screw terminal torque ................................. 0.5 Nm
Relative humidity ......................................... < 95% RH (non-cond.)
Dimensions, without display front (HxWxD) . 109 x 23.5 x 104 mm
Dimensions, with display front (HxWxD) ..... 109 x 23.5 x 116 mm
Protection degree ........................................ IP20
Weight ......................................................... 250 g / 265 g with 4501
DIN rail type ................................................. DIN 46277
Current input:
Measurement range .................................... 3.5...23 mA
Sensor error detection:
Loop break 4...20 mA .......................... < 1 mA
Input voltage drop:
Supplied unit ........................................ < 4.5 V
Non-supplied unit ................................ < 6 V
Current output:
Signal range (span) ...................................... 3.5...23 mA
Load (max.) .................................................. 20 mA / 600
Ω
/ 12 VDC
Load stability ...............................................
≤
0.01% of span / 100
Ω
Current limit .................................................
≤
28 mA
General values
Input type
Absolute
accuracy
Temperature
coefficient
All
≤
±0.1% of span
≤
±0.01% of span / °C
Basic values
Input type
Basic
accuracy
Temperature
coefficient
mA
≤
±16 µA
≤
±1.6 µA / °C
EMC immunity influence ..................................... < ±0.5% of span
Extended EMC immunity:
NAMUR NE 21, A criterion, burst ....................... < ±1% of span