9116 - Product Version 9116-003
27
To default state 1.0
sCROlling HElP TExTs in DisPlay linE 3
[01]
[02]
[03]
[04]
[05]
[06]
[07]
[08]
[09]
[10]
[11]
[12]
[13]
[14]
[15]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[24]
[25]
[26]
[27]
[28]
[29]
[30]
[31]
[34]
[37]
[38]
[39]
[41]
[42]
[43]
[44]
[45]
[46]
[47]
[48]
[49]
[50]
[51]
[52]
[53]
[54]
[55]
[56]
[57]
[58]
[59]
[60]
[61]
[62]
[63]
[64]
Set correct password
Enter Advanced setup menu?
Select Temperature input
Select Potentiometer input
Select Linear resistance input
Select Current input
Select Voltage input
Select 0.0-1 V input range
Select 0.2-1 V input range
Select 0-5 V input range
Select 1-5 V input range
Select 0-10 V input range
Select 2-10 V input range
Select 0-20 mA input range
Select 4-20 mA input range
Select 2-Wire sensor connection
Select 3-Wire sensor connection
Select 4-Wire sensor connection
Set Resistance value low
Set Resistance value high
Select Celsius as temperature unit
Select Fahrenheit as temperature unit
Select TC sensor type
Select Ni sensor type
Select Pt sensor type
Select Display unit
Select Decimal point position
Set Display range low
Set Display range high
Select Relay setpoint in % of input range
Select Relay setpoint in display units
Select Pt10 sensor type
Select Pt20 sensor type
Select Pt50 sensor type
Select Pt100 sensor type
Select Pt200 sensor type
Select Pt250 sensor type
Select Pt300 sensor type
Select Pt400 sensor type
Select Pt500 sensor type
Select Pt1000 sensor type
Select Ni50 sensor type
Select Ni100 sensor type
Select Ni120 sensor type
Select Ni1000 sensor type
Select TC-B sensor type
Select TC-E sensor type
Select TC-J sensor type
Select TC-K sensor type
Select TC-L sensor type
Select TC-N sensor type
Select TC-R sensor type
Select TC-S sensor type
Select TC-T sensor type
Select TC-U sensor type
Select TC-W3 sensor type
Select TC-W5 sensor type
Select TC-Lr sensor type
Select OFF function - relay is permanently off
Select POWER function - relay indicates power status OK
Select ERROR function - relay indicates sensor error only
Select WINDOW function - relay is controlled by 2 setpoints
Select SETPOINT function - relay is controlled by 1 setpoint
Select Normally Closed contact
Select Normally Open contact
Set Relay setpoint
Select Action on decreasing signal
Select Action on increasing signal
Set Relay hysteresis
Select No error action - undefined status at error
Select Open relay contact at error
Select Close relay contact at error
Select Hold relay status at error
Set Relay ON delay in seconds
Set Relay OFF delay in seconds
Select Contact is Closed Inside Window
Select Contact is Open Inside Window
Set Relay window setpoint low
Set Relay window setpoint high
Set Relay window hysteresis
Select Internal temperature sensor
Select CJC connector (Accessory)
Select Open relay contact at error
Select Close relay contact at error
Select 0-20 mA outout range
Select 4-20 mA output range
Select 20-0 mA output range
Select 20-4 mA output range
Select No error action - output undefined at error
Select Downscale at error
Select Namur NE43 downscale at error
Select Namur NE43 upscale at error
Select Analogue output response time in seconds.
Set Temperature for analogue output low
Set Temperature for analogue output high
Enter SIL setup
Enter Simulation mode
Enter Rail setup
Perform Process Calibration
Enter Language setup
Enter Password setup
Enter Display setup
Perform Memory operations
Load saved configuration into module
Save configuration in display front
Adjust LCD contrast
Adjust LCD backlight
Write a 5-character channel TAG
Show Analog output value in display
Show TAG on display
Alternate shown information in display
Calibrate Input low to process value?
Calibrate Input high to process value?
Enable input simulation?
Set the input simulation value
Relay simulation - use
1
to toggle relay
Enable Password protection?
Set New password
Enable Fastset functionality?
Relay setpoint - press
3
to save
Relay setpoint - Read only
Select Language
Use process calibration values?
Set value for low calibration point
Set value for high calibration point
Enable Rail status signal output?
Enable SIL configuration lock?
0...20 mA is not a valid output range for SIL
operation