42
9116 - Product Version 9116-003
9116QF01
LERBAKKEN 10, 8410 ROENDE DENMARK
Revision date:
2012-06-08
Version Revision
V6 R0
Prepared by:
PB
Page:
3/4
Ui, Vmax
30 V
Ii, Imax
120 mA
Pi
900 mW
Ci
3 nF
Li
2
μ
H
Module 9116B 1/2
Terminal 52-54
Uo, Voc
28 V
IIC or A,B
80 nF
4 mH 54
μ
H/
Ω
Io, Isc
93 mA
IIB or C,E,F
640 nF
16 mH 218
μ
H/
Ω
Po
650 mW
IIA or D,G
2.1
μ
F
32 mH 436
μ
H/
Ω
Uo, Voc
21.4 V
IIC or A,B
0.16
μ
F
4 mH 54
μ
H/
Ω
Io, Isc
93 mA
IIB or C,E,F
1.13
μ
F
16 mH 218
μ
H/
Ω
Po
650 mW
IIA or D,G
4.15
μ
F
32 mH 436
μ
H/
Ω
Module 9116B2
Terminal 52-54
Group
Co
Lo
Lo/Ro
Lo/Ro
Module 9116B1
Terminals 52-54
Group
Co
Lo
T
+
-
54
53
52
51
44
43
42
41
9116
34
33
32
31
14
13
12
11
Power Rail
4501
54
53
52
51
44
43
42
41
9116
34
33
32
31
14
13
12
11
Power Rail
4501
Unclassified Location or
Hazardous Classified Location
Class I, Division 2 Group A,B,C,D T4
or Class I, Zone 2, Group IIC T4
Hazardous Classified Location
Class I/II/III, Division 1, Group A,B,C,D,E,F,G
or Class I, Zone 0/1 Group IIC, [AEx ia] IIC
or Class I, Zone 0/1 Group IIC, [Ex ia] IIC
4-20 mA
Loop-powered
transmitter
(terminal 11,12,13,14)
(terminal 31,32,33,34)
(terminal 91,92,93,94,95)
U
m:
253 V max. 400 Hz
Status relay, terminal (33,34)
Non hazardous area installation
Voltage max: 125 VAC / 110 VDC
Power max:
62.5 VA / 32 W
Current max: 0.5 A AC / 0.3 ADC
Zone 2 installation:
Voltage max: 32 VAC / 32 VDC
Power max:
16 VA / 32 W
Current max: 0.5 A AC / 1 A DC
Relay output, terminal (13,14)
Non hazardous area installation
Voltage max: 250 VAC / 30 VDC
Power max:
500 VA / 60 W
Current max: 2 A AC / 2 ADC
Zone 2 installation
Voltage max: 32 VAC / 30 VDC
Power max:
64 VA / 60 W
Current max: 2 A AC / 2 ADC
-20 ºC
≤
Ta
≤
+60ºC