5
●
LUBRICATION
To ensure smooth movement of gobos and zoom and focus lens, it’s advised rotators’ bearings and 2 sliding bars for zoom and f
ocus
lens be lubricated every 2 months. High quality and high temperature lubricant/grease is advised..
●
TROUBLESHOOTING
PROBLEM
ACTION
The projector doesn’t switch on
Check the fuse on the power socket.
Check the lamp.
The lamp is on but the projector doesn’t respond
to the controller
Make sure that
the fixture’s start address is right
Replace or repair the XLR signal cable.
The projector functions intermittently
Make sure the fan is working well or fans and their shields are not blocked
Beam appears dim, Low in brightness
Make sure the lamp is within its lifespan
Remove dust or grease from the lenses.
The project image appears to have a halo
Carefully clean
the lamp,
optical lenses and other components.
Heavily Defective Beam
Check if lens are in good condition(not cracked)
Clean dust or grease on the lens.
3.
APPEARANCE
4.
INSTALLATION
A projector can be placed on the stage floor directly or mounted on a truss at any direction without impacting its performance. Please
use a safety cord
, which can support 10 times the weight of the projector, while mounting it on the truss
. The safety cord should be
used with magazine with a lock
. Just as the figures below, please run the safety cord
through the holes at the bottom of the base and
around the truss.
●
RIGGING
1. Use M12 bolt to
fix the clamp
(1) into the omega holder
(3), run the bolt through the holder’s holes
2. Push 2 quick-lock fasteners(4) into holes at the bottom of the
base, fix them and tighten them clockwise
3.Run safety cord(2) through holes at the bottom of the base and around the truss(6)
Arm
Base
Body
Summary of Contents for PR-2204A
Page 19: ...19 10 CIRCUITDIAGRAM ...