32 |
GB
•
Use the tool that is recommended in this manual.
This is how to ensure that your machine provides
optimum performance.
•
Keep your hands away from the working area when
the machine is in operation.
•
Before performing setting or maintenance work, re
-
lease the start button and pull out the power plug.
Warning!
This electric tool generates an electromagnetic field
during operation.
This field can impair active or passive
medical implants under certain conditions.
In order to
prevent the risk of serious or deadly injuries, we recom
-
mend that persons with medical implants consult with
their physician and the manufacturer of the medical im
-
plant prior to operating the power tool.
6. Technical data
AC motor
220 – 240 V~ 50 Hz
Nominal power S1*
2000 Watts
Idle speed n
0
5000 rpm
Hard metal saw blade
ø 305 x ø 30 x 2.8 mm
Number of teeth
48
Maximum tooth width of
the saw blade
3 mm
Pivot range
-45 ° / 0° / +45 °
Mitre cut
0° to 45° to the left
Saw width at 90°
340 x 105 mm
Saw width at 45°
240 x 105 mm
Saw width at 2 x 45°
(double mitre cut)
240 x 60 mm
Cutting heigth/width
(chop cut)
180 mm / 20 mm
Protection class
II /
Weight
approx. 20.9 kg
Laser class
2
Attention:Laser beam
Do not look into the beam
Laser class 2
Protect yourself and your environment from acci-
dents using suitable precautionary measures!
•
Do not look directly into the laser beam with unpro
-
tected eyes.
• Never look into the path of the beam.
•
Never point the laser beam towards reflecting sur
-
faces and persons or animals. Even a laser beam
with a low output can cause damage to the eyes.
•
Caution - methods other than those specified here
can result in dangerous radiation exposure.
• Never open the laser module.
Unexpected exposure
to the beam can occur.
•
The laser may not be replaced with a different type
of laser.
•
Repairs of the laser may only be carried out by the
laser manufacturer or an authorised representative.
Residual risks
The electric tool is state-of-the-art and has been
built according to the recognised technical safety
regulations. However, individual residual risks can
arise during operation.
•
Health hazard due to electrical power, with the use
of improper electrical connection cables.
•
Furthermore, despite all precautions having been
met, some non-obvious residual risks may still re
-
main.
•
Residual risks can be minimised if the “safety in
-
structions” and the “Proper use” are observed along
with the whole of the operating instructions.
•
Do not load the machine unnecessarily: excessive
pressure when sawing will quickly damage the saw
blade, which results in reduced output of the ma-
chine in the processing and in cut precision.
•
When cutting plastic material, please always use
clamps: the parts which should be cut must always
be fixed between the clamps.
• Avoid accidental starting of the machine: the start
button may not be pressed when inserting the plug
in an outlet.