2.  Installation of the fencing systems 

1.

Foundations

-

To obtain the best result, it is advisable to level the ground over the whole length of the fence

-

For correct positioning, maintain the centre-centre distances. The distance is determined by the 

post system and the type of panel being installed

-

Align the fence line

-

To determine the dimensions of the foundations it is advisable to consult a specialised engineer to 

evaluate wind load and solar conditions and any other factors requiring specialist opinion 

(concrete quality directive B30)

-

In case of direct installation the post needs to be supported as long as necessary

Post system 

Panel Type

SEC FLAT/2D/3D

SEC 4D

Bekafix Ultra

2538 mm 

(+/- 2)

2843 mm

(+/- 2)

Centre-centre distance table

7

09/11/2020 – Securifor

®

- Installation manual

Summary of Contents for BETAFENCE Securifor

Page 1: ...Securing What Matters Securifor Installation manual EN...

Page 2: ...2 09 11 2020 Securifor Installation manual Bekafix Ultra Securifor post systems...

Page 3: ...stallation of the fencing systems 1 Foundations 2 Installation of posts panels 3 Installation U Profile 4 Optionally bottom fixations 5 Number of spider fixators per post 6 Making corners 7 Installati...

Page 4: ...polyester coated This type of post can be installed with Securifor flat Securifor 2D Securifor 3D Securifor 4D panels Each post has holes every 150 mm for attachment of the clamps with security bolts...

Page 5: ...ols Spider fixators to attach the panel to the post at the side They can be fixed with M6x50 mushroom head square neck bolts DIN603 washer M6 and self breaking off nut M6 all in stainless steel Securi...

Page 6: ...ent of the upper side of the Securifor panels The general rule is that flat Securifor Securifor 3D panels should always be installed with U profiles on top regardless of the way of installation U prof...

Page 7: ...nstalled Align the fence line To determine the dimensions of the foundations it is advisable to consult a specialised engineer to evaluate wind load and solar conditions and any other factors requirin...

Page 8: ...sts to both sides of the first panel Attach the spider fixators to the first post Temporarily attach two spider fixators to the second post top and bottom to keep the panel in position Place the first...

Page 9: ...tra posts are installed according to the post panel post system Fix a second panel to the second post with spider fixators in the correct positions Now it s possible to remove the temporary fixators o...

Page 10: ...n of posts panels Detail of the 4 different systems Securifor Securifor 2D Securifor 3D The post cap is mounted the other way round INSIDE INSIDE OUTSIDE INSIDE OUTSIDE OUTSI DE Securifor 4D OUTSI DE...

Page 11: ...ay of installation a U profile on top is required For extra security a bottom fixation can be added see next slide for solutions of fixation at the bottom For the installation of Securifor 2D Securifo...

Page 12: ...breaking nut M8 thickness concrete plate 40mm 2 An L profile that s fixed to the bottom of the panel For extra security this profile can also be fixed to a concrete foundation When installing on a wal...

Page 13: ...height Post length fixators intermediate corner post fixators end post 2m 2575mm 14 7 2 4m 2475 3175mm 16 8 3m 3775mm 20 10 Post for installation on footplate In combination with Securifor Panels the...

Page 14: ...o be made For an acute angle the post with the panel making the acute angle is placed into the same foundation hole as the last line post OUTSI DE 150 110 INSIDE INSIDE OUTSI DE Inner corners possible...

Page 15: ...building a fence on a slope using the Bekafix Ultra post it is best to start at the highest point of the site Where the site slopes the next panel should just be placed lower according to need Is to p...

Page 16: ...ion with concrete slabs A concrete slab can be placed in the middle of the Bekafix Ultra post The same installation principle applies post panel concrete slab post panel concrete slab width 4cm height...

Page 17: ...upport Maximum loading of this piece is 50 kg In case of special requirements it s advised to contact a project engineer for strength calculations SLANTING SUPPORT single or double For extra security...

Page 18: ......

Reviews: