3.3 Electric Power
Make sure that the electrical characteris cs of building electric network
follow the technical specifica ons of the oven which can be found on the
iden fica on plate located on the back panel and in the electrical table
below.
Use a dedicated circuit breaker for the oven, that must be located at least 6
(1.8 m) away from the right sides of the oven.
USA - CANADA
Voltage
Frequency
Power
Circuit Breaker
Consump on
60 Hz
5.7 kW
30 A
4 kWh
Phases
Single
Cable
Socket
3x10AWG
NEMA 6-30
NEMA 6-30
EUROPA
Voltage
Frequency
Power
Circuit Breaker
Consump on
230 V
50 Hz
7.2 kW
32 A
5 kWh
Phases
Single
Cable
3x4mm²
Socket
32A(2P+T)
32A(2P+T)
Power
Cable
Exhaust
Outlets
3"
(76 mm)
6
(1.8m)
Maximum
Distance
Circuit Breaker
Air Inlet
208/240 V