If the fuel does not drain from the drain container, then remove-and replace the draining valve for the new one
( s e e 72-02-00, Table 203, Stem 71). Repeat the false starting and check the operation of the v a l v e .
(7)
Accomplish the check of the draining valve for proper operation during the engine run (refer to DRAINING
VALVE AND DRAIN CONTAINER - INSPECTION AND CHECK)
(8)
Tighten the leaky connections.
Safety wire the valve (3) to the combustion chamber casing. Safety wire the nut (6) and the nuts of the pipes (7)
and (8).