background image

www.prattsafety.com

INTERNATIONAL 

info

@

prattsafety.com

AUSTRALIA 

1300 133 226 

info

@

prattsafety.com.au

NEW ZEALAND 

0800 133 226 

info

@

prattsafety.co.nz

PRODUCT DATA SHEET

Model No: 

PSPCS

PRATT PORTABLE DECONTAMINATION SHOWER

SHOWER SET UP OPERATION & TAKE DOWN:

1.

  Attach water supply hose to inlet hose nozzle.  

 

Minimum water pressure should be 210kPa.

2.

  Ensure shower valve is turned off (T handle  

 

is horizonal).

3.

  Turn water supply on.

4.

  Test shower by turning on shower valve (T handle  

 

is vertical) and operate for 15-30 seconds to ensure  

 

correct operation.

5.

  Turn shower valve off. Shower is now ready for use  

 

when required.

6.

  After use, shower should be fully de-contaminated,  

 

cleaned and dried.

7.

  Shower should also be inspected for damage,  

 

or missing parts and should be completely  

 

dry before storage.

8.

  Disassemble and store in carry bag to protect shower  

 

from sunlight and other environmental conditions.

HOW TO USE THE SHOWER:

1.

  Open the shower valve (T handle is vertical). Allow about  

 

10 seconds to reach full spray pattern.

2.

  Stand within water spray pattern and rotate body slowly  

 

to receive full benefit of decontamination spray.

3.

  Remove any contaminated clothing.

4.

  Continue to rotate body and remain within shower for  

 

at least 15 minutes.

5.

  Seek further medical attention.

EFFECTIVE SPRAY PATTERN:

1.

  The most effective spray pattern creates a wall of water  

 

by overlapping the spray and keeping the spray  

 

in a vertical plain with the upright portion of the shower.

2.

  All shower spray nozzles should be facing inward  

 

so that the water sprays meet at the centre.

3.

  The optimum spray pattern can be attained with  

 

a minimum pressure of 210kPa.

SHOWER INSPECTION & MAINTENANCE:

1.

  As with all emergency equipment this shower unit  

 

should be inspected regularly to ensure all components  

 

are included in the carry bag.

2.

  Also conduct a visual inspection of the components  

 

to ensure there is no damage or missing parts or affect  

 

from other contaminants.

3.

  It is recommended the shower unit is assembled and  

 

operated on a regular basis to ensure proper operation  

 

and that the connectors and seals are in good condition.

4.

  Occasional coating of a silicone based lubricant on the  

 

connectors will ensure they function smoothly.

850mm

2005mm

860mm

Reviews: