Functional characteristics
MIG/MAG welding
42
Item No.: 099-004838-PRA01
5.2.6.11
Program changeover with standard torch (P8)
In "Latched absolute program sequence", the machine starts at the first cycle with absolute program 1.
Releasing the torch trigger (2nd cycle) switches over to absolute program 2 when the "tstart" ignition time
expires. Otherwise the control remains in absolute program 1 and switches to absolute program 2 after
"tstart" elapses.
In the third cycle (torch trigger pressed), the machine switches to absolute program 3. After "t3" elapses,
the control switches over automatically to absolute program 4.
The functional sequence is only available if no other accessory components, such as remote control or
special torch, are connected.
The programs cannot be switched over on the wire feed machine control during the welding process.
Figure 5-15