Page
15
of
30
Operating the stapler
Regulating the stapler with the operating pressure
You can set the penetration depth of the stapler into the material by regulating the operating
pressure. At a higher operating pressure, the nails are driven deeper into the material; setting a
lower operating pressure reduces the penetration depth.
Set the operating pressure to achieve the required penetration depth. This has the
following benefits:
•
you save energy (compressed air),
•
you reduce the noise level, and
•
you reduce the wear of the stapler.
Proceed as follows to set the operating pressure:
➢
Adjust the pressure at the pressure valve of the compressor or compressed air system.
➢
Observe the pressure reading.
Checking the penetration depth
➢
Shoot a staple into a sample workpiece with the same characteristics as the processing
material.
➢
Repeat these steps until you have set the required penetration depth.
Summary of Contents for 11-WP130
Page 7: ...Seite 7 von 30 Beschreibung ...
Page 25: ...Seite 25 von 30 Schaltpläne Pneumatikplan Elektroplan ...
Page 26: ...Seite 26 von 30 ...
Page 35: ...Page 7 of 30 Description ...
Page 53: ...Page 25 of 30 Circuit diagrams Pneumatics diagram ...
Page 54: ...Page 26 of 30 Electrical diagram ...