Faults
26
Fault
Possible cause
Corrective measure
Intake filter contaminated.
Clean or replace intake filter.
Piston clearance, 3rd stage, too
large.
Check piston clearance and replace parts.
Notify aftersales service (see page 27).
G
Intermediate pressure safety valve blows
off.
Intermediate pressure too high,
valves leaking.
Check valves.
Notify aftersales service (see page 27).
H
Compressor becomes too hot
Cooling air supply deficient.
Check setup.
Ambient temperature too high.
Max. ambient tempe40°C
Suction / pressure valve leaking.
Check and if necessary replace valves.
Notify aftersales service (see page 27).
I
High oil consumption
Piston, piston rings and / or cylinder
worn.
Replace parts.
Notify aftersales service (see page 27).
Intake filter contaminated.
Clean or replace intake filter.
Compressor too hot.
Improve cooling.
Accessory ordering
You can reorder accessories from the manufacturer (see page 27). Use only original PREBENA accessories
or PREBENA-approved accessories to operate the compressor.
Ordering other accessories
All types
Art. No.
Accessories
Z 200.40
PREBENA special oil
00205801
Adapter for refilling KT-1000 compressed-air cylinders
KT-3500-S
2 x KT-3500 compressed-air cylinders in a metal transport case
KT-1000-SY
5 x KT-1000 compressed-air cylinders in a Systainer (plastic transport case)
You can find more accessories at
Compressor disposal
ATTENTION
Incorrect disposal results in environmental damage.
Clean the compressor before disposing of it.
Observe the valid regulations for the disposal of oil.
Never dispose of the compressor or parts of it with normal household waste. If you
wish to dispose of the compressor, send it to PREBENA. PREBENA can guarantee