background image

Notes 

 

24 

Notes 

 

Summary of Contents for VITAS 45

Page 1: ...________________________________________ PREBENA Wilfried Bornemann GmbH CO KG Seestra e 20 26 63679 Schotten Germany Tel 49 0 60 44 96 01 0 Fax 49 0 60 44 96 01 820 info prebena com www prebena de Or...

Page 2: ...compressor should be trained under the guidance of skilled user This operating manual is intended for those who operate these compressors make cleaning of these compressors utilize these compressors...

Page 3: ...or 9 Data are on the plate with characteristics 9 Preparation of the compressor to start operation 10 Compressor unpacking 10 Checkup 10 Functional check of the compressor without edge device 11 Contr...

Page 4: ...type of danger To the right of it you see a signal word indicating the degree of danger Be low there is a description of source of danger and instructions on its prevention DANGER Instructions with t...

Page 5: ...nn GmbH Co is not be liable for any damage arising from the misuse of the equipment Safety rules to avoid the injury possibility The compressor should be out of reach of children and unqualified staff...

Page 6: ...iceous items and materials presence close to the compressor Make sure that the compressor is not absorbed flammable corrosive or toxic gases Safety rules to avoid the compressor failure The compressor...

Page 7: ...in accordance with DIN EN ISO 3744 2000 14 LWA 1s 78 dB A LPA 72 dB A Ratio operating time downtime 65 35 Ambient temperature 5 C bis 40 C Minimum distance from wall 50 cm Explanation 1 Compressor sc...

Page 8: ...riven compressors for personal use Safety valve Automatic starting and shutdown system of pressure relay Automatic motor breaker Power supply 230 V except TWINSTAR 690 Air receiver with volume 4 l Tot...

Page 9: ...following meanings Sticker Meaning Warning on hot surfaces Data are on the plate with characteristics Plate with characteristics is pasted on compressor casing It contains the following data Plate wit...

Page 10: ...ents by using faulty compressor Check condition of the compressor before each use Make sure that the compressor is in perfect condition In particular check the following If the safety valve is faultle...

Page 11: ...40 C Make sure that the minimum distance is complied between the compressor and any possible obstacle to air flow is 50 cm Before starting make sure that voltage and supply frequency correspond to da...

Page 12: ...imum pressure see technical specifications starting from page 7 Maximum allowable operating pressure produced by the compressor is limited automatically by the pressure relay Safety valve limits addit...

Page 13: ...our edge device on pressure reducer 2 o Turn clockwise increases pressure o Turn counterclockwise lowers pressure Turn of reducer on 90 changes operating pressure on about 0 5 bar Operating pressure o...

Page 14: ...GER In case of opening of union nipple a freely suspended pressure hose can cause severe or fatal injuries Secure firmly pressure hose Proceed as follows Press union nipple of pressure hose to the qui...

Page 15: ...r the compressor transportation distances more than 10 m distances over uneven surfaces and moving in unusual position Transportation of compressor over long distances is allowed only in the original...

Page 16: ...moisture Drain of condensate moisture from the high pressure receiver Condensing moisture condensate is collecting on the bottom of the receiver The volume of condensate depends on the load of compres...

Page 17: ...ed in tap water Completely wipe with a dry soft duster Lubricate all metal parts of the compressor with a thin layer of special oil Prebena Cleaning the air filter Effective cleaning of absorbing air...

Page 18: ...ompetent specialist Please refer to our authorized partners providing the services They can provide workers who have passed the expert examination These requirements apply only to the Federal Republic...

Page 19: ...a brush dampened in soap solution Air bubbles will show the place of the air outflow These connections to be firmly tightened If the air continues to enter contact the service depart ment see page 21...

Page 20: ...0 42B Air distributor 2 branches Z140 44B Air distributor 3 branches Z170 80B Air gun from light alloy metal with a connecting nipple Z175 80 Gun for tyre pumping with kit of adapters Additional compo...

Page 21: ...a in case of non compliance of this condition warranty from the manufacturer does not work and thus warranty requirements are not possible The warranty does not cover consumables such as for example o...

Page 22: ...nction 8 Description 7 Product Overview 7 Dispose 20 Drain of condesate moisture 16 I Injuries Avoid 5 protective equipment 5 Intended use 5 Misuse 5 L Long distances 15 M Maintenance 16 Cleaning the...

Page 23: ...Index 23 Long distances 15 Short distances 15 Transporttation 15 Troubleshooting 19 U Unpacking 10 W Warrenty 21...

Page 24: ...Notes 24 Notes...

Reviews: