background image

1. INTRODUCTION

3

Inground 3

1.2 Dimensions

Inground 6

WWW.PRECILUM.COM

SQUARE SHAPE 100x100

ROUND SHAPE Ø100

11

3

Ø91

70

11

0

Ø75

11

7

SQUARE SHAPE 130x130

ROUND SHAPE Ø130

Ø116

11

3

79

Ø96

14

9

SQUARE SHAPE 150x150

ROUND SHAPE Ø150

Ø142

14

6

85

Ø114

Inground 9

INGROUND 3 + INGROUND 6 + INGROUND 9 WHITE

INSTRUCTIONS MANUAL v1.1

Summary of Contents for INGROUND 3 WHITE

Page 1: ...INGROUND 3 INGROUND 6 INGROUND 9 WHITE ON OFF INSTRUCTIONS MANUAL Round Square ...

Page 2: ...INTRODUCTION 2 SAFETY AND OPERATION 3 INSTALLATION 4 CONNECTION DIAGRAMS 5 CARE AND MAINTENANCE 6 TECHNICAL SPECIFICATION 7 WARRANTY STATEMENT 2 4 5 12 13 14 15 FOR YOUR OWN SAFETY PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE BEGINNING SETUP AND INSTALLATION LED Electrostatic Sensitive Device EDS ...

Page 3: ...pability these Inground fixtures are capable of meeting most exterior applications The refined thermal management system incorporates a sleek and robust heat sink directly into the fixture to ensure maximum heat transfer and long life time 1 1 About the product WWW PRECILUM COM INGROUND 3 INGROUND 6 INGROUND 9 WHITE INSTRUCTIONS MANUAL v1 1 ...

Page 4: ...RECILUM COM SQUARE SHAPE 100x100 ROUND SHAPE Ø100 113 Ø91 70 110 Ø75 117 SQUARE SHAPE 130x130 ROUND SHAPE Ø130 Ø116 113 79 Ø96 149 SQUARE SHAPE 150x150 ROUND SHAPE Ø150 Ø142 146 85 Ø114 Inground 9 INGROUND 3 INGROUND 6 INGROUND 9 WHITE INSTRUCTIONS MANUAL v1 1 ...

Page 5: ...e wired according to respective electrical standards The manufacturer shall not be liable for any modifications of the product of incorrect installation of the product Never install the luminaire on rain fog or high humidity CAUTION DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT CAUTION THE POWER SUPPLY MUST BE UNPLUG FROM THE MAINS POWER BEFORE CONNECTING ANY ...

Page 6: ...nd check that it completely disappear within 30 min If it doesn t work study a further drainage system Aluminum sleeve must be installed on drainage layers surrounding concrete layers and leveled with external finish MIN 200 CONCRETE EXTERNAL FINISH PLASTIC SLEEVE IP BOX WIRING DRAINAGE WWW PRECILUM COM INGROUND 3 INGROUND 6 INGROUND 9 WHITE INSTRUCTIONS MANUAL v1 1 ...

Page 7: ...th the surrounding floor Fig 1 Fig 2 Fig 3 Fig 1 Edges of the plastic sleeve must not be installed above the surrounding floor Fig 2 Edges of the plastic sleeve must not be installed under the surrounding floor Fig 3 OK 90 NOT ALLOWED WWW PRECILUM COM NOT ALLOWED INGROUND 3 INGROUND 6 INGROUND 9 WHITE INSTRUCTIONS MANUAL v1 1 ...

Page 8: ... stainless steel face ring Do not remove tempered glass Fig 5 Connect the cable coming out of the luminaire with the supply cable in the IP juction box more about IP connection in 3 3 IP BOX connection Put the luminaire into the plastic sleeve Fig 6 Unscrew WWW PRECILUM COM INGROUND 3 INGROUND 6 INGROUND 9 WHITE INSTRUCTIONS MANUAL v1 1 ...

Page 9: ... 7 Put on the stainless steel front ring which you removed in step 5 Fig 5 Fig 8 Put on and tighten the screws which you removed in step 4 Fig 4 Check if the screws are tight properly Fig 9 WWW PRECILUM COM Tighten the screws Tighten the screws INGROUND 3 INGROUND 6 INGROUND 9 WHITE INSTRUCTIONS MANUAL v1 1 ...

Page 10: ...3 INSTALLATION 9 MAX 500kg WWW PRECILUM COM NOT ALLOWED NOT ALLOWED NOT ALLOWED INGROUND 3 INGROUND 6 INGROUND 9 WHITE INSTRUCTIONS MANUAL v1 1 ...

Page 11: ...ire L Live black brown Wire N Neutral blue Wire PE Earth yellow green 3 INSTALLATION 10 3 2 1 Wiring ON OFF option 3 2 Connection WWW PRECILUM COM INGROUND 3 INGROUND 6 INGROUND 9 WHITE INSTRUCTIONS MANUAL v1 1 ...

Page 12: ...ction boxes containing electrical connections If the IP rating of the connection is not observed the complaint will not be accepted For example https www etelec com prodotto mpgel Video tutorial https www youtube com watch v tj6ksKdzuE0 PRECILUM requirement 3 INSTALLATION 11 3 3 IP BOX connection WWW PRECILUM COM INGROUND 3 INGROUND 6 INGROUND 9 WHITE INSTRUCTIONS MANUAL v1 1 ...

Page 13: ...AGRAMS 12 4 1 ON OFF option IP Junction box 230V 3 x 1 5 mm Description Must be specified by the electrical designer WWW PRECILUM COM Luminaire 1 2 3 XX INGROUND 3 INGROUND 6 INGROUND 9 WHITE INSTRUCTIONS MANUAL v1 1 ...

Page 14: ...g covering in order to verify any damage Check that all the seals are in good condition and that they are not dry damaged or split Check the glass or plastic screen for damage and replace if required Check for water inside the luminaire s housing and its recessing box The internal components such as the ballasts transformers washers and screws must not show clear signs of oxidation or rust Clear t...

Page 15: ...3000K 4000K 5700K and other accor req See datasheet 230V 50Hz AC Option 24V DC INGROUND 3 WHITE 4W current 350mA INGROUND 6 WHITE 8W current 350mA INGROUND 9 WHITE 12W current 350mA 70 000 hrs L70 25 C 20 C 40 C Housing die cast aluminium Cover clear hardened glass stain steel face ring See dimensional drawing IP67 INGROUND 3 WHITE 0 7 kg INGROUND 6 WHITE 0 8 kg INGROUND 9 WHITE 1 5 kg See website...

Page 16: ...um provides a product warranty for a period of five 5 years from date of purchase Please refer www precillum com for all warranty terms and conditions WWW PRECILUM COM INGROUND 3 INGROUND 6 INGROUND 9 WHITE INSTRUCTIONS MANUAL v1 1 ...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...Please check for latest updates and changes on the Precilum website 2021 PRECILUM s r o ALL RIGHT RESERVED All specifications subject to change without notice WWW PRECILUM COM ...

Reviews: