3.3 Fitting
3 - 26
© Precitec GmbH & Co. KG • EN 09/2019
3.3.2
Connecting the laser fibre to the laser head
(trained personnel only)
Connecting the laser fibre
Fig. 3-2
Fitting: Laser fibre
(e.g. QBH socket)
Attention – Clean workplace!
Only carry out any maintenance and repair work on the laser head in a clean
workplace.
Before connecting the laser fibre remove any dirt in the three bayonet contours
and in the plug.
Laser fibre
- To prevent any dust or dirt getting into the fibre socket accidentally,
we recommend that you connect the laser fibre when the optics are in a
horizontal position.
292-1060-01pc
Locking area
A
B
1.
Remove the protective film/ protective cap from the fibre socket.
2.
Insert the
(correctly aligned)
fibre plug into the unlocked fibre socket up to the stop.
Attention:
Before inserting the plug make sure that its bayonet contour is aligned with the
red marks on the locking cap and socket
(see detailed view
A
).
3.
Carefully turn the locking cap to the first stop, then lift and lock it
(see detailed view
B
).
The white mark on the locking cap must be within the fibre socket's white locking area.
Tip:
The (white) locking area helps you to visually check whether or not the socket is
locked correctly.
Locking or unlocking
the socket is not permitted when the plug is not inserted.