6.4 Parts available (LightCutter 3D only)
6 - 62
© Precitec GmbH & Co. KG • EN 09/2019
Fitting the ceramic part and nozzle
6.4
Parts available
(LightCutter 3D only)
Table 6-2
Appendix: Parts available
(LightCutter 3D)
1.
Insert the ceramic part into the sensor insert (4) carefully.
Note the locating pins on the ceramic part when doing this – they must engage into the
sensor insert.
The nozzle and the nut must only be tightened by hand
(do not use any tools)
.
Otherwise the ceramic part could be damaged.
In addition to this, make sure that the contact surfaces on these parts are clean.
2.
Screw the ceramic part to the sensor insert (4) hand-tight using the nut.
3.
Screw the nozzle (1) into the ceramic part hand-tight.
Name
Designation
Number
Parts available
Sensor insert
SE LightCutter 3D
P 0580 – 92320
Connecting flange
(SE)
AA SE LightCutter 3D
P 0580 – 92313
Ceramic part
KT
KT M1.5" KN
P 0494 –
752 – 00001
Nut
MU
MU KN
P 0494 –
940 – 00001
Nozzles
(DE) -
(nozzle electrodes)
DE M1.5" KN ø2.0
DE M1.5" KN ø1.5
DE M1.5" KN ø1.2
DE M1.5" KN ø1.0
P
P
P
P
0494
0494
0494
0494
–
–
–
–
857
855
854
853
–
–
–
–
00020
00015
00012
00010