6 Specific characteristics of the 3D version
© Precitec GmbH & Co. KG • EN 09/2019
6 - 59
6.2.3.3
Aligning the sensor insert
(HF socket, sensor system)
Fig. 6-8
Installation: Sensor insert - Alignment
(HF socket, 3D version)
The sensor insert mount can be aligned ±20°.
Unscrew the sensor insert
(SE)
(see figure)
and align the connecting flange
±20°using the screws
(4 x M4x14)
.
If the HF socket
(sensor system)
position on the machine is not suitable, the sensor insert
can be aligned 4 x 90° using the connecting holes on the laser head
(bottom)
.
Fig. 6-9
Installation: Sensor insert - Alignment
(4x90°, 3D version)
±20°
4 x M4x14
±20°
2
1
Size 3
1
Sensor insert
SE
2
Connecting flange
(laser head - SE)
4 x 90°
4 x M4x14
2
1
2
Size 3
Please note the washers and insulating sockets for the fixing screws
(4 x M4x14)
when aligning the connecting flange
(4 x 90°)
.