Procedure 5.1 - Troubleshooting the Lower and Upper
Interconnect Cables
Anti-static kits can be ordered from Precor (part number 20024-101).
Troubleshooting the Upper Interconnect Cable
1.
Set the on/off switch in the “off” position.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
2.
Attach the anti-static wrist strap to your arm, then connect the ground lead of the wrist strap
to the units frame.
3.
Remove the four bolts that fasten the front half of the frame to the rear half of the frame. The
upper interconnect cable connects to the lower interconnect cable where the two frame
halves are joined. Carefully, slide the front half of the frame away from the rear half of the
frame.
4.
Remove the rear cover. For convenience, the upper interconnect cable is the cable that
attaches to the upper PCA and the lower interconnect cable is the cable that connects to the
lower PCA.
5.
Disconnect the upper interconnect cable from the upper PCA and the lower interconnect
cable.
6.
Connect a known good upper interconnect cable from the lower interconnect cable to the
upper PCA. Route the cable outside of the unit at this time.
7.
Check operation as described in Section Three.
8.
If the unit operated correctly when the new interconnect cable was installed...
THEN...
OTHERWISE...
The original upper interconnect cable
The original upper interconnect cable
is bad; install a new cable as described
is not bad; continue with the next step.
in Procedure 6.5.
9.
Reconnect the original upper interconnect cable to the upper PCA.