5.17 Ellipitical Fitness Crosstrainer
Page 52
Procedure 6.14 - Replacing the Step-Up Pulley Belt
1.
Set the on/off switch in the “off” position and disconnect the power adapter from the EFX.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
2.
Remove the rear covers as described in Procedure 6.1.
3.
Remove the stairarm assemblies as described in Procedure 6.22.
4.
Remove the crankarm assemblies as described in Procedure 6.10.
5.
Remove tension from the drive belts and remove the pillow block bearings per Procedure
6.11, steps 4 to 7.
6.
Slide the step up and input belts off of the input pulley shaft and remove the input pulley and
eddy current disc assembly from the drive unit. (See Diagram 6.10)
7.
Remove the left and right tension bolts, locking tabs and brackets. Slide the step up pulley
assembly with both the step up and input belts out of the drive unit.
8.
Remove the step up pulley belt and place the replacement step up pulley belt in it’s place on
the step up pulley assembly.
9.
Set the step up pulley assembly with the step up and input belt at it’s mounting position in
the drive unit. Replace the tensioning bolts, locking tabs and brackets removed in step 8.
Thread the left and right tension bolts into the step up pulley shaft.
10. Slide the step up and input belts onto the input pulley shaft as you set the input pulley shaft
in it’s mounting position in the drive unit.