background image

9.23, 9.27 Treadmill

Page 27

Procedure 5.7 - Troubleshooting the External A.C. Power 

Source

It is extremely important that any Precor treadmill be connected to and operated on a dedicated 
15 amp A.C. circuit. A 15 amp dedicated circuit is defined as: a circuit fed by a 15 amp circuit 
breaker that feeds a single load. A treadmill operating from a non-dedicated circuit or a circuit 
breaker of less than 15 amps capacity will not have the necessary power available to operate 
normally under higher load conditions. The lack of available power can cause any number of 
symptoms ranging from numerous intermittent (seemingly inexplicable) error conditions, poor 
speed control, or tripping the house circuit breaker.
If any of the above symptoms exist the external A.C. circuit must be checked and confirmed to be 
a 15 amp dedicated circuit 

before

 troubleshooting the treadmill.

In addition the A.C. voltage must be checked. Nominal A.C. operating voltage on 120 Vac circuits 
is 105 Vac to 120 Vac. Nominal A.C. operating voltage on 240 Vac circuits is 208 Vac to 240 
Vac.
For operator safety considerations and to minimize electrostatic discharge conditions the A.C. 
frame ground continuity must also be verified to be a low resistance connection to the A.C. 
distribution ground bar.

Important

If the A.C. circuit feeding a treadmill is found to be a non-dedicated circuit or a circuit equipped 
with a circuit breaker with a capacity of less than 15 amps, the A.C. circuit must be corrected to 
be a 15 amp dedicated circuit 

before

 any reliable troubleshooting can be performed on the 

treadmill. More importantly, a non-dedicated circuit may constitute a safety hazard to the 
treadmill operator.

120 Vac Systems

120 Vac distribution systems utilize a single pole circuit breaker (hot lead) and a neutral lead 
connected to a common neutral (ground) bar. The A.C. safety ground (green wire) is connected 
to a separate ground bar in the distribution system.

The most common problems found are (1) the circuit is fed by a circuit breaker of less than 20 
amp capacity, (2) the circuit breaker correctly feeds a single A.C. outlet but the neutral is 
common between several A.C. outlets and (3) both the hot and neutral leads feed several A.C. 
outlets. The appropriate correction action or actions (see below) must be followed if any of the 
above conditions exist. 

Corrective actions should only be undertaken by a licensed 

electrician.

1.

The circuit breaker feeding the treadmill is not a 15 amp circuit breaker.

If the circuit breaker is greater than 15 amps, the circuit breaker should be replaced with a 
15 amp circuit breaker. If the circuit breaker is less than 15 amps the circuit breaker must be 
replaced with a 15 amp circuit breaker and the wiring from the A.C. distribution must be 
capable of safely handing 15 amps. If the A.C. wiring is under sized, it must be replaced 
with wire capable of safely handling 15 amps. Please, refer to local electrical codes when 
determining the appropriate wire size for a 15 amp circuit.

Summary of Contents for 9.21

Page 1: ...n this product This document contains general product information software diagnostic procedures when available preventative maintenance procedures inspection and adjustment procedures troubleshooting...

Page 2: ...cedures Perform inspection procedures when a trouble symptom points to a particular problem and after removing and replacing major components Many maintenance problems can be fixed by adjusting variou...

Page 3: ...3 cm Width 30 5 inches 77 5 cm Height 55 inches 140 cm Running surface 20 inches by 59 inches 51 cm by 149 9 cm Motor 2 75 hp continuous duty DC Speed 0 5 to 12 mph 0 8 to 19 3 kph 10 mph is equivale...

Page 4: ...2 error occurs all drive motor and lift motor motion is halted and the display is blanked except for the error display E4 This error is displayed in the display s TIME window indicating an incomplete...

Page 5: ...rrent exceeds 28 amps the current limit circuit is activated When current limit is activated the drive motor current and speed can not be increased MOT DRV Indicates a defective drive motor circuit Ty...

Page 6: ...s the ENTER key to toggle the display to the hour meter 3 HOUR will appear in the main window and the treadmill s hours of use will be displayed in the time window in the format XXXXX XX Pressing the...

Page 7: ...the INCLINE S and SPEED T keys until the display goes blank The word init will appear in the display s time window The EEPROM has now been cleared and reset After 1 1 4 seconds 1 25 will be displayed...

Page 8: ...version 2 2 and greater contain the option of selecting U S Standard or metric measurements 1 Within 2 seconds of power up press the STOP INCLINE S and SPEED T keys sequentially 2 Press one of the arr...

Page 9: ...ormation Model and serial number Provide the model number as accessed in Procedure 2 2 Program number running when the problem occurred A description of a What happened or failed to happen b The actio...

Page 10: ...sage PRESS QUICKSTART OR PROGRAM 3 Place the treadmill in Manual Mode Adjust the speed of the running belt to 2 3 m p h Operate the treadmill for at least 5 minutes a Concentrate on the feel of the ru...

Page 11: ...o the 0 incline position unless it is already in the 0 incline position 4 Press the QUICKSTART key when the running belt starts the incline will move to its 0 incline position unless it is already in...

Page 12: ...pright position Set the on off switch in the on position Place the treadmill in the manual program and operate the incline several times between its minimum and maximum incline positions to ensure tha...

Page 13: ...pounds 5 If the drive belt tension is less than 70 or greater than 90 pounds slightly loosen the four drive motor mounting nuts The drive motor mounts on slotted holes allowing the drive motor to be m...

Page 14: ...23 9 27 Treadmill Page 14 Diagram 4 3 Drive Motor Mounting 6 Plug the AC power cord into the AC outlet and set the treadmill circuit breaker in the on position 7 Check treadmill operation per Section...

Page 15: ...witch in the off position and remove the AC power cord from the AC outlet 3 Remove the four screws that fastens the backplate to the rear of the console and remove the backplate Refer to Diagram 6 9 T...

Page 16: ...ect replace the console per Procedure 6 10 6 If all of the above measurements are good but a keypad key is still not functioning replace the upper PCA per Procedure 6 11 7 If you have performed all of...

Page 17: ...ing the value of the internal potentiometer The lift motor is initially set at a known starting position calibration See Procedure 4 1 subsequent motor movement is tracked via the potentiometer resist...

Page 18: ...gnificantly high replace the incline motor per Procedure 6 1 8 Connect an AC voltmeter between terminal 2 white wire and terminal 3 black wire of the JK4 connector on the lower PCA Press the INCLINE T...

Page 19: ...onnections on the incline potentiometer to ensure they are securely connected to the incline potentiometer Refer to Diagram 5 3 Diagram 5 3 Incline Potentiometer 16 Repeat the three ohmmeter measureme...

Page 20: ...d Sensor 2 Remove the treadmill s hood 3 Remove the JK2 connector from the lower PCA Refer to Diagram 5 2 4 With an ohmmeter measure between the two pins on the JK2 connector and slowly push the runni...

Page 21: ...itch per Procedure 6 7 5 Ensure that the safety key magnet is operating the reed switch in the console If the reed switch is not activated the display will not illuminate See Procedure 5 5 6 Remove th...

Page 22: ...9 23 9 27 Treadmill Page 22 Diagram 5 5 Circuit Breaker and On Off Switch Circuit Breaker Reset Button On Off Switch AC Power Cord...

Page 23: ...iagram 5 6 JK1 Connector Lower PCA 14 With a DC voltmeter measure between VCC orange wire and GND green wire on the JK1 connector on the lower PCA The reading should be approximately 16 Vdc If the rea...

Page 24: ...rom the upper PCA 3 With an ohmmeter measure between the two pins of the JK5 connector with the safety key installed on the console in its operating position and with the safety key removed from the c...

Page 25: ...et the on off switch in the on position 4 Set the treadmill to operate in the manual program at 1 mph 5 With a DC voltmeter measure between the T3 M terminal and the T4 M terminal on the lower PCA The...

Page 26: ...Procedure 6 11 13 If the display does not indicate that the speed should be increasing when the SPEED S key is pressed bypass the interconnect cable with a known good interconnect cable It is not nece...

Page 27: ...t breaker with a capacity of less than 15 amps the A C circuit must be corrected to be a 15 amp dedicated circuit before any reliable troubleshooting can be performed on the treadmill More importantly...

Page 28: ...ircuit breaker If the circuit breaker is greater than 15 amps the circuit breaker should be replaced with a 15 amp circuit breaker If the circuit breaker is less than 15 amps the circuit breaker must...

Page 29: ...cline motor to its upper mounting bracket 7 Remove the incline motor from the treadmill 8 Set the replacement incline motor at its mounting position and fasten it to its upper mounting bracket with th...

Page 30: ...lift tube to rotate The incline motor may require calibration if the incline motor s lift tube has rotated 4 Remove the two bolts that fasten the lift platform to the frame and remove the lift platfor...

Page 31: ...are removed in step 5 9 Set the replacement lift platform in its mounting position and fasten it with the hardware removed in step 4 10 Fasten the incline motor s lift tube to the lift platform with t...

Page 32: ...two screws that fasten the lower PCA to the frame and remove the lower PCA from the treadmill 6 Set the replacement lower PCA at its mounting position and fasten it with the hardware removed in step 4...

Page 33: ...and remove the speed sensor from the treadmill Diagram 6 3 Speed Sensor 5 Set the replacement speed sensor at its mounting position and fasten it with the hardware removed in step 4 6 Dress the speed...

Page 34: ...hould be replaced as a unit 4 Disconnect the red and black drive motor wires from the lower PCA and green yellow wire from its frame ground Diagram 6 4 Drive Motor Mounting 5 Loosen the four drive mot...

Page 35: ...e T4 M terminal of the lower PCA the red wire removed in step 3 to the T3 M terminal of the lower PCA and the green yellow lead to its frame ground termination 10 Dress the drive motor wires and faste...

Page 36: ...emove the circuit breaker from the mounting plate refer to Diagram 6 5 Diagram 6 5 Circuit Breaker 4 Press the replacement circuit breaker into its mounting hole until it snaps into place 5 Connect th...

Page 37: ...ress the four clips on the on off switch two on the top and two on the bottom and push the on off switch out of the front of its mounting plate Refer to Diagram 6 6 Diagram 6 6 On Off Switch 5 Orient...

Page 38: ...wire from the AC power cord to the lower right hand terminal of the on off switch the red wire from the circuit breaker to the upper left hand terminal of the on off switch and the red black wire from...

Page 39: ...ng to disengage from the brush holder and slide out of the brush holder 5 Disconnect the brush connector and remove the brush from the brush holder 6 Slide the replacement brush into the brush holder...

Page 40: ...hey are a 28 pin dual in line package DIP28 and a forty four pin square package PLCC44 Each of these packages should be removed with a proper IC removal tool see the illustrations below 4 The IC s may...

Page 41: ...9 23 9 27 Treadmill Page 41 5 Perform Procedure 2 3 upper PCA to lower PCA initialization Notch Notch PLCC44...

Page 42: ...View 4 Disconnect the interconnect cable from the JK1 connector on the lower PCA Cut and remove the cable ties that retain the interconnect cable 5 Remove four screws that fasten the console to the ta...

Page 43: ...connector on the upper PCA 12 Snap the safety switch removed in step 6 into its mounting on the console Connect the safety switch connector to the SW1 connector on the upper PCA 13 Set the safety swit...

Page 44: ...nect the keypad connector from the JK5 connector on the upper PCA 6 When furnished disconnect the heart rate connector from the JK2 connector on the upper PCA 7 Remove the five screws that fasten the...

Page 45: ...f the upper end of the targa upright Stop when the string is projecting out of the upper and lower ends of the targa upright Remove the interconnect cable from the string and discard the interconnect...

Page 46: ...te to the console and remove the backplate Refer to Diagram 6 9 4 Disconnect the safety switch connector SW1 from the upper PCA Unsnap the safety switch from its mounting in the console 5 Snap the rep...

Page 47: ...9 23 9 27 Treadmill Page 47 Wiring Diagram 7 1 9 23 9 27 Treadmills...

Page 48: ...9 23 9 27 Treadmill Page 48 Block Diagram 7 2 9 23 9 27 Treadmills...