Continue with the next step.
The Heart Rate system is operating
correctly. There is no need to continue
with this procedure.
6.
Hold the Heart Rate Test Transmitter (Precor part number 20045-101) near the display
housing. If the
HEART RATE
indicator on the electronic console blinks with the LED on the
Smart Rate Test Generator
...
THEN...
OTHERWISE...
The chest strap assembly is bad.
The heart rate receiver assembly is
Wear a new chest strap assembly
bad. Replace the heart rate receiver as
when you use the Heart Rate
described in Procedure 5.4 of the
System.
Residential Treadmill Service Manual.
7.
Press
ENTER
to return to the User ID.