Note:
The original nuts used to mount the lift motor are Kep nuts, which do not require a separate
washer. If you do not use Kep nuts to mount the lift motor, use washers when you mount the lift
motor to the treadmill frame.
27. Return the treadmill to an upright position.
28. Connect the black lift motor lead to the terminal of the lift motor capacitor that already has a
black wire.
29. Connect the red lift motor lead to the terminal of the lift motor capacitor that already has a
red wire.
30. Connect the connector on the white lift motor lead that connects the lift motor to pin 4 of
lower PCA connector J3.
31. Connect the molex connector on the rotation sensor wire assembly to connector J2 on the
lower PCA.
32. Connect the two blue wires on the rotation sensor wire assembly to the terminals on the
zero sense switch terminals.
33. Calibrate the treadmill lift assembly as described in Procedure 4.1 of this appendix.
34. Check the operation of the treadmill as described in Section Three of this appendix, then
replace the hood as described in Procedure 5.1 of the Residential Treadmill Service
Manual.