9.55 Treadmill
Page 1-26
Page 26
Procedure 6.2 - Replacing the Lift Platform
1.
Set the treadmill circuit breaker in the “off” position. Remove the AC line cord from the AC
outlet.
2.
Remove the treadmill hood. Carefully, lay the treadmill on it’s right side.
3.
Remove the hitch pin and clevis pin that fastens the lift motor tube to the lift platform. While
the lift tube is not fastened to the lift platform, care must be taken to not allow the lift tube to
rotate. If the lift tube rotates, the lift motor must be re-calibrated per Procedure 4.1.
4.
Remove the four bolts (2 each side) that fasten the lift platform to the treadmill frame. See
Diagram 6.1. Remove the lift platform from the treadmill.
Diagram 6.1 - Lift Platform Mounting
5.
Set the replacement lift platform in it’s mounting position. Start all four lift platform bolts.
Securely tighten all four lift platform bolts.
6.
Fasten the lift platform to the lift motor tube with the clevis and hitch pins removed in step 3.
Do not allow the lift tube to rotate.
7.
Check treadmill operation per Procedure 3.
Mounting
Bolt