9.55 Treadmill
Page 1-8
Page 8
13. The error log will store up to 10 error conditions. The errors are logged with the most recent
error in position one. When a new error condition occurs, each existing error is pushed down
one position in log. If there was an error in position 10 when a new error was logged, the
error that was in position 10 will be lost.
14. Each error in the log will show the odometer reading (in miles) and the time (hour meter)
when the error occurred. The errors are displayed as;
1 ER20 1234567 MI 12345 HRS.
15. The arrows keys will allow you to scroll through the log. When the first unused position is
reached in the log, the message
NO MORE ERRORS
will be displayed.
16. When the
QUICK START
key is held for 2 seconds the message
HOLD TO CLEAR
ERRORS
will be displayed. If the
QUICK START
key is held for an additional 2 seconds, the
message
CLEARED
will be displayed. When the
QUICK START
key is released the
message
NO MORE ERRORS
will be displayed and all error are erased from the log.
17. Press the
RESET
the
ENTER
key to exit the information display.
Summary of Contents for 9.55
Page 43: ...9 55 Treadmill Page 43 Wiring Diagram 7 1 9 55 version 1 ...
Page 46: ...9 55 Treadmill Page 1 46 Page 46 Wiring Diagram 7 4 9 55 120 Vac version 2 ...
Page 47: ...9 55 Treadmill Page 47 Wiring Diagram 7 5 9 55 240 Vac version 2 ...
Page 48: ...9 55 Treadmill Page 1 48 Page 48 Block Diagram 7 6 9 55 120 Vac version 2 ...
Page 49: ...9 55 Treadmill Page 49 Block Diagram 7 7 9 55 240 Vac version 2 ...