If the video signal can be verified up to the tuner, connect a known
good signal directly into the mini-coax on the tuner. If the
channel lineup on the console has been confirmed correct, the signal
is good, the unit has been rebooted, the software is correct on all
components, and the screen is still black, the tuner has likely
failed. Replace the entire console.
Black Screen - Full Console
Description
Console displays only a black screen. Machine is unusable.
Possible Causes
1
Console has frozen
2
Console is attempting to boot to an image that has corrupted
3
Touch screen has failed
Possible Remedies
1
Reboot the machine to resolve any software freezing issues.
2
If the console is attempting to boot to a corrupted software image,
when a reboot is performed, the CPA version number will scroll
across the display of the machine controls, but the screen will
remain black and will never reach the Precor splash screen. Perform
a 7 Power Cycle (See Boot Screen Procedure below) to force the
machine to revert to the backup image. When the unit boots
successfully, reflash the unit with the correct software to ensure
that the old, corrupted image has a usable image installed.
3
If the touch screen has failed, the entire console will need to be
replaced.
Boot Screen Procedure
Summary of Contents for AMT 823
Page 2: ......
Page 61: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 59...
Page 81: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 79...
Page 107: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 105...
Page 199: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 197...
Page 379: ...rfJ R BK BR Bl 0 d I w l 0 1 LO iftMotor...
Page 380: ......
Page 382: ......