Hardware
Validation
horizontal movement in both directions. At maximum
stride length the low stride display should read 0 and
the high stride display should read 40.
Vertical
Position Test
Press the
key
VERTICAL POSITION TEST will scroll across the
display.
Press the
OK
key
Displays a digital representation of vertical
movement of the stairarms.
Press the
CLEAR
key to return to
Hardware
Validation
Stride Count
Reset
Press the
key
STRIDE COUNT RESET
will scroll across the
display.
Press the
OK
key.
When
STRIDE COUNT RESET
is selected,
CONTINUE PEDALING, AND PRESS OK TO
RESET BELT STRIDE COUNT will scroll across the
display.
Note: The STRIDE COUNT
RESET is used to CLEAR the
stride count to zero only when
the support belts are replaced.
Press the
OK
key
to CLEAR the stride
count.
Or
Press the
CLEAR
key to cancel the
Stride Count Press
the
OK
key.Reset
and return to
Hardware
Validation.
If the OK key is pressed, the software executes the
following steps.
1
Clears the LPCA belt stride count to
zero.
2
Increments the LPCA value to show
how many times the belt has been
replaced.
3
Log the odometer into LPCA with the
stride count of the last belt
replacement.
4
Clears the UPCA belt stride count to
zero.
5
Increments the UPCA value to show
how many times the belt has been
replaced.
6
Log the odometer into UPCA with the
stride count of the last belt
replacement.
Summary of Contents for AMT 823
Page 2: ......
Page 61: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 59...
Page 81: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 79...
Page 107: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 105...
Page 199: ...Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 197...
Page 379: ...rfJ R BK BR Bl 0 d I w l 0 1 LO iftMotor...
Page 380: ......
Page 382: ......