C534i Elliptical Fitness Crosstrainer
Page 35
Procedure 7.2
- Replacing a Display Front Panel, Upper PCA, Heart
Rate PCA or Metrics PCA
Procedure
The keyboard is part of the display housing front panel. If the keyboard is not functioning prop-
erly, replace the display housing front panel.
Removing the Display Housing Front Panel
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in Sec-
tion One, Things You Should Know.
1.
Attach an anti-static wrist strap to your arm, then connect the ground lead of the wrist strap
to the frame of the EFX.
2.
Remove the upper and lower bracket covers from the rear of the display.
3.
Remove display top and the rear cover from the display. If you are only replacing the heart
rate PCA, skip to step 13.
4.
Disconnect the heart rate cable and the data cable from the rear of the upper PCA. See
Diagram 6.2.
5.
Release the six snaps that fasten the display face to the display, see Diagram 6.2. Lift the
display face off of the display.
Removing and Replacing the Upper PCA
6.
Disconnect the metrics PCA cable, the keypad cable and the D pad cable from the upper
PCA. See Diagram 6.3.
7.
Remove the upper PCA by carefully unsnapping it from its mounts on the display front panel
and slide it out of the two holding clips.
8.
Position the replacement upper PCA at its mounting location on the display housing front
panel, slide it into the two holding clips and press it into place in its mounts on the display
front panel.
9.
Reconnect the metrics PCA cable, the keypad cable and the D pad cable. See Diagram 6.3.
10. Set the display face in its mounting position and reconnect the heart rate cable. Snap the
display face onto the display, working from the bottom to the top.
11. Remove the ground lead of the wrist strap from the EFX frame, then remove the wrist strap
from your arm.
12. Skip to step 24.