C546 Elliptical Fitness Crosstrainerl
Page 109
Procedure 7.30 - Replacing a Power Entry Module Fuse
(version 2,3 units manufactured after 10-15-2000)
Procedure
1.
Set the on/off switch in the off position. Remove the A.C. line cord from the A.C. outlet and
from the power entry module.
2.
Using a thin bladed screwdriver, carefully pry the fuse access door open (See Diagram
7.28).
Diagram 7.28 - Power Entry Module Fuse
3.
Using the thin bladed screwdriver, carefully pry the fuse module out of the power entry
module.
4.
The fuse module contains two fuses, carefully pry one or both fuses out of the fuse module,
as required.
5.
Snap the replacement fuse(s) into the fuse module.
6.
Slide the fuse module back into the power entry module and close the fuse access door.
Fuse
Fuse Module
Fuse Access Door
Power Entry Module