C546 Elliptical Fitness Crosstrainer
Page 8
Procedure 3.2 - Accessing the Diagnostic Program (version
1)
The EFX diagnostic software cycles through the following tests:
•
LED Diagnostics
•
Power Bits
•
Lift Calibration Number
•
Heart Rate
•
Keypad Test
Procedure
1.
Plug the power cord into the wall outlet, then turn on the EFX with the circuit breaker.
2.
Press keys
RESET,5,1,7,6,5,7,6,1
., sequentially.
3.
Watch the upper display as the LED test progresses. The test will illuminate every LED on
the display. The test will illuminate the LED’s in a specific pattern. When you are familiar
with the pattern, it is easy to determine when a LED does not illuminate.
4.
If you do not observe the LED illumination sequences described in Step 3
...
THEN...
OTHERWISE...
Replace the upper PCA as described
The LED test passed successfully;
in Procedure 7.2 or 7.3.
continue with the next step.
5.
Power Bits will be displayed. Power bits indicates the amount of power being applied to the
eddy current magnets and will vary directly with the resistance. Press
ENTER
to continue.
6.
With
LIFT
displayed in the right display window, watch the right display window (shown in
Diagram 3.1). Press the
CROSSRAMP
▲
or
CROSSRAMP
▼
keys one at a time. Verify that
the lift calibration number increments or decrements as each of the
CROSSRAMP
keys are
pressed.
Summary of Contents for C546
Page 55: ...C546 Elliptical Fitness Crosstrainerl Page 55 section to the front cover section ...
Page 111: ...C546 Elliptical Fitness Crosstrainerl Page 111 Wiring Diagram 8 1 C546 120 Vac version 1 ...
Page 112: ...C546 Elliptical Fitness Crosstrainer Page 112 Block Diagram 8 2 C546 120 Vac version 1 ...
Page 114: ...C546 Elliptical Fitness Crosstrainer Page 114 Block Diagram 8 4 C546 240 Vac version 1 ...
Page 116: ...C546 Elliptical Fitness Crosstrainer Page 116 Block Diagram 8 6 C546 120 Vac version 2 3 ...
Page 118: ...C546 Elliptical Fitness Crosstrainer Page 118 Block Diagram 8 8 C546 240 Vac version 2 3 ...