C546 Elliptical Fitness Crosstrainer
Page 90
Procedure 7.20 - Replacing the Eddy Current Magnet
Assembly
Removing the Magnet Assembly
1.
Set the on/off switch in the “off” position, then unplug the power cord from the wall outlet.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
2.
Remove the rear cover.
3.
Disconnect the magnet cable from the magnet assembly.
4.
Remove the bolts that secure the magnet assembly to the drive unit. Remove the magnet
from the drive unit.
Diagram 7.18 - Eddy Current Magnet
Replacing the Magnet Assembly
5.
Position the magnet assembly at its mounting position.
6.
Replace and hand tighten the magnet assembly mounting bolts. Torque the magnet
assembly mounting bolts to 60 in/lbs.
Magnet
Mounting
Bolt
Eddy
Current
Magnet
Centering
Bolts
Current
Eddy
Disk
Summary of Contents for C546
Page 55: ...C546 Elliptical Fitness Crosstrainerl Page 55 section to the front cover section ...
Page 111: ...C546 Elliptical Fitness Crosstrainerl Page 111 Wiring Diagram 8 1 C546 120 Vac version 1 ...
Page 112: ...C546 Elliptical Fitness Crosstrainer Page 112 Block Diagram 8 2 C546 120 Vac version 1 ...
Page 114: ...C546 Elliptical Fitness Crosstrainer Page 114 Block Diagram 8 4 C546 240 Vac version 1 ...
Page 116: ...C546 Elliptical Fitness Crosstrainer Page 116 Block Diagram 8 6 C546 120 Vac version 2 3 ...
Page 118: ...C546 Elliptical Fitness Crosstrainer Page 118 Block Diagram 8 8 C546 240 Vac version 2 3 ...