C844 Upright Cycle
Page 5
Procedure 2.1 - Performing C844 Cycle Diagnostics
This procedure tests or displays the following:
•
Display Array
•
Seven Segment Displays
•
Baseline Resistance
•
Software Revision Number
•
Heart Rate Diagnostic
•
Power Bits
•
Keypad Test
1.
Plug the power cord into the wall outlet, then turn on the cycle with the ON/OFF switch.
2.
With the
PRECOR C844
banner scrolling, press the
STOP
,
WORK LEVEL UP
and
WORK
LEVEL
DOWN
keys simultaneously.
3.
Verify that the entire left display window illuminates, then two diagonal lines sweep across
the display.
4.
Watch the electronic display as the LED test progresses. This test is programmed to display
the following LED illumination sequence:
a. Every LED on the left display window illuminates simultaneously;
b. Horizontal, vertical, and diagonal lines of illuminated LED’s sweep across the left display
window;
c. The right display windows illuminate, then decrement from 8.8.8.8 to 0.0.0.0;
d. The function LED’s illuminate simultaneously and then extinguish; and
e. Each function LED illuminates separately and then extinguishes.
5.
If you do not observe the LED illumination sequence described in the previous steps . . .
THEN . . .
OTHERWISE . . .
Replace the upper PCA as described
Continue with the next step.
in Procedure 7.1.